Description
M12 threaded sensing for metal targets
The XSZ M12 cylindrical inductive range is designed to detect metal targets without contact. The supplied series information covers two mounting arrangements: a flush version with a listed 2 mm sensing distance and a non-flush version with a listed 4 mm sensing distance.
Those figures describe different versions, not two settings on one sensor. Choose the exact model around the target material, available mounting space, required output and controller connection.
Flush and non-flush versions
The old series data gives different reference targets and response-frequency entries for each mounting style. Compare them as separate versions; the exact orderable codes and mounting drawings still need to be matched to the application.
| Series data | Flush mount | Non-flush mount |
|---|---|---|
| Listed sensing distance | 2 mm ± 10% | 4 mm ± 10% |
| Standard iron target | 12 × 12 × 1 mm | 15 × 15 × 1 mm |
| Listed response frequency | 1 kHz | 800 Hz |
The reference distances use different iron target sizes. For other metals or smaller targets, the usable sensing distance may differ; confirm the selected model under the actual target and mounting conditions.
Electrical and environmental specifications
The following are entries from the supplied M12 series description. Output choices are not mapped to individual model codes, so use the selected model’s current datasheet before wiring or specifying a machine.
Target, power and output
| Detectable target | Magnetic metal; the source notes reduced sensing distance for non-magnetic metals |
|---|---|
| Operating voltage | 10–30 VDC; 12–24 VDC nominal |
| Supply ripple | 10% maximum, peak-to-peak |
| Load current | 200 mA maximum |
| Residual voltage | 1.5 V maximum |
| Current consumption | 10 mA maximum |
| Output options described | NPN or PNP; normally open or normally closed, depending on model |
Protection, connection and temperature
| Circuit protection described | Reverse power-supply polarity protection |
|---|---|
| Connection described | Pre-wired cable; cable length and wiring colors not supplied |
| Operating temperature | −25 to +70 °C |
| Storage temperature | −40 to +80 °C |
Where an M12 metal sensor can fit
An M12 threaded sensor may be considered where a machine needs to detect a metal part or position within limited mounting space. Examples to evaluate include metal-carrier presence, fixture position and metal-part counting. The source does not establish a specific coolant rating or guaranteed production-line speed.
Selection and installation checks
- Choose flush or non-flush mounting from the available space and the model-specific installation drawing.
- Compare the real target’s metal, size and position with the listed iron reference target.
- Match supply voltage, NPN/PNP output and NO/NC behavior to the controller input using the correct wiring diagram.
- Confirm response requirements, cable length, ambient conditions and order quantity for the exact model.
Frequently asked questions
Is the 4 mm distance available on the flush version?
The supplied data assigns 2 mm to the flush version and 4 mm to the non-flush version. Check the exact model and target conditions before ordering.
Will a non-magnetic metal be detected at the listed distance?
The source says the sensing distance decreases for non-magnetic metals. It does not provide a correction factor, so test or verify the actual metal and target size.
Can one sensor switch between NPN and PNP or NO and NC?
The series description lists these as output options but does not say they are switchable on one unit. Select the model code with the required output.
What is needed before connecting the sensor?
Confirm the selected model’s current wiring diagram, wire colors, supply range, load and controller input. The supplied series material does not include a model-specific connection drawing.