Description
2 mm shielded metal detection in an M12 body
The XSZ PR12-2DN is the DC NPN normally open model in the M12 shielded proximity-sensor range. Its listed sensing distance is 2.0 mm ±10%, with a 0–1.6 mm setting distance.
Those distances are specified against an iron 12 × 12 × 1 mm reference target. Check the actual metal, target size and operating gap before fixing the sensor position; non-magnetic metals may be detected at a shorter distance.
Select the shielded format for the mounting layout
A shielded M12 sensing head can be considered when the active face needs to sit within a metal mounting area. Confirm the permitted flush position in the PR12-2DN drawing; the thread size alone does not establish the exact bracket dimensions or mounting tolerance.
The NPN normally open output should be matched to the controller input and switching sequence using the approved wiring diagram. Other NPN, PNP and two-wire codes in the range are separate products, not settings on PR12-2DN.
PR12-2DN technical specifications
Check the current PR12-2DN datasheet before finalizing electrical ratings, mounting dimensions or environmental requirements.
Detection and construction
| Model / installation | PR12-2DN / M12 shielded |
|---|---|
| Sensing distance | 2.0 mm ±10% |
| Setting distance | 0–1.6 mm |
| Standard target | Iron, 12 × 12 × 1 mm |
| Detectable material | Magnetic metal; distance decreases for non-magnetic metal |
| Hysteresis | Less than 10% of sensing distance |
| Housing / sensing face | Nickel-plated brass / ABS |
Electrical and environment entries
| Output | DC NPN, normally open |
|---|---|
| DC supply | 12–24 VDC listed; confirm the exact permitted range and ripple limit before wiring |
| Consumption current | Less than 13 mA, NPN/PNP DC series entry |
| Control-output entry | Less than 300 mA for NPN/PNP DC series; confirm allowable load |
| Circuit protection | Reverse-connection, surge absorption and load short-circuit protection, listed for DC series |
| Operating / storage environment | −30 to +65 °C; no freezing or condensation; 35–95% RH |
| Insulation resistance | At least 50 MΩ at 500 VDC, between live parts and housing |
| Protection class | IP67 listed; confirm for this exact model |
Other shielded M12 model codes
The codes below are separate products, not output choices that can be changed on PR12-2DN.
| PR12-2DN2 | DC NPN normally closed |
|---|---|
| PR12-2DP / PR12-2DP2 | DC PNP normally open / normally closed |
| PR12-2DO / PR12-2DC | DC two-wire normally open / normally closed |
| PR12-2AO / PR12-2AC | AC two-wire normally open / normally closed |
Installation checks for the selected model
- Compare the actual metal target and size with the 12 × 12 × 1 mm iron reference.
- Plan the working gap within the listed 0–1.6 mm setting distance, then confirm margin under real conditions.
- Check the approved flush-mount drawing, body length and bracket dimensions.
- Confirm the actual permitted DC supply, NPN wiring, connector or cable, output load and controller input.
- Check the exact-model environmental and IP rating if they are critical to the installation.
Frequently asked questions
What is the difference between sensing and setting distance?
The listed sensing distance is 2.0 mm ±10%; the setting distance is 0–1.6 mm. Use the latter as a starting point for the installed operating gap, then verify performance with the real target.
Can the PR12-2DN sensing face sit flush with metal?
It is listed as a shielded model. Confirm the permitted flush position and any clearance in the exact-model mounting drawing before machining the bracket.
Can PR12-2DN be switched to PNP or two-wire output?
No such switching is established. The supplied matrix assigns PNP and two-wire configurations their own model codes.
Which electrical details still need confirmation?
Confirm the exact permitted supply range, NPN wiring, connector or cable and allowable output load against current PR12-2DN documentation.