PR18-5DN M18 5 mm Shielded Proximity Sensor

The XSZ PR18-5DN is an M18 shielded proximity sensor with a source-listed 5 mm ±10% sensing distance, 0–4 mm setting distance and DC NPN normally open output. Its reference target is iron measuring 18 × 18 × 1 mm. Confirm the actual target, permitted supply range and wiring before installation.

  • Factory Direct Supply
    Stable Quality
  • Custom Options
    Support OEM/ODM
  • Technical Support
    Quick Response

Description

M18 shielded sensing with a 5 mm reference distance

The XSZ PR18-5DN is the DC NPN normally open model in the M18 shielded proximity-sensor range. Its source-listed sensing distance is 5 mm ±10%, with a 0–4 mm setting distance.

The distance is specified against an iron 18 × 18 × 1 mm standard target. Actual detection depends on the metal and target size; the supplied specifications note a shorter sensing distance for non-magnetic metals.

What this model is designed to match

PR18-5DN combines the M18 shielded form with an NPN normally open output. It is the model to review when the controller requires that specific output type and a close-range metal target must be checked against the listed reference and setting distances.

A shielded designation does not replace the exact mounting drawing. Confirm sensing-face position, surrounding-metal clearance, body length and the actual cable or connector before machining a bracket or wiring a controller.

PR18-5DN technical specifications

The entries below come from the supplied M18 shielded model matrix and shared series table. Confirm electrical limits and environmental ratings against current PR18-5DN documentation before final design.

Detection and construction

Model / formatPR18-5DN / M18 shielded
Sensing distance5 mm ±10%
Setting distance0–4 mm
Standard targetIron, 18 × 18 × 1 mm
Detectable targetMagnetic metal; shorter distance for non-magnetic metals
HysteresisLess than 10% of sensing distance, series-listed
Housing / sensing faceNickel-plated brass / ABS, series-listed

Electrical and environmental entries

OutputDC NPN, normally open
DC supply12–24 VDC listed; confirm the permitted operating range and ripple limit
Consumption currentLess than 13 mA, NPN/PNP DC series entry
Control-output entryLess than 300 mA, NPN/PNP DC series entry; confirm allowable load
Circuit protectionReverse-connection, surge absorption and load short-circuit protection, listed for DC series
Operating / storage environment−30 to +65 °C; no freezing or condensation; 35–95% RH
Insulation resistanceAt least 50 MΩ at 500 VDC, between live parts and housing, series-listed
Protection classIP67 listed; verify for this exact model

Related M18 shielded model codes

The following are separate source-listed products. PR18-5DN is not shown as a field-switchable PNP, NC, two-wire or AC sensor.

PR18-5DN2DC NPN normally closed
PR18-5DP / PR18-5DP2DC PNP normally open / normally closed
PR18-5DO / PR18-5DCDC two-wire normally open / normally closed
PR18-5AO / PR18-5ACAC two-wire normally open / normally closed

Selection and installation checks

  • Compare the real metal target and dimensions with the iron 18 × 18 × 1 mm reference.
  • Plan the working gap against the listed 0–4 mm setting distance, then check margin with the installed target.
  • Verify the exact mounting drawing for the shielded sensing face, body length and surrounding-metal clearance.
  • Confirm the permitted DC supply, NPN NO wiring, cable or connector, controller input and allowable output load.
  • Check exact-model environmental and IP ratings if those are critical to the installation.

Frequently asked questions

What are the sensing and setting distances?

The source lists a 5 mm ±10% sensing distance and a 0–4 mm setting distance, using an iron 18 × 18 × 1 mm standard target. Verify the usable gap with the actual target.

Can PR18-5DN detect non-magnetic metals?

The supplied specifications say it can detect non-magnetic metals at a reduced sensing distance, but do not provide a reduction factor. Test the specific material and geometry.

Can this model be changed to PNP or normally closed?

The supplied model matrix gives PNP and normally closed configurations different product codes. No field conversion is established for PR18-5DN.

Which details need confirmation before wiring?

Confirm the approved voltage range, NPN NO pinout or wire colors, cable or connector type, controller-input compatibility and output-load limit against current exact-model documentation.

Reviews

There are no reviews yet.

Be the first to review “PR18-5DN M18 5 mm Shielded Proximity Sensor”

Your email address will not be published. Required fields are marked *