M8 10 mm Magnetic Proximity Switch

The XSZ M8 magnetic proximity switch is a shielded M8 series with a listed 10 mm sensing distance, 0-8 mm setting distance, and a phi 8 x 2 mm magnet standard target. The source lists a 42 mm body length, IP67 protection, DC supply information, and source-listed DC two-wire and AC two-wire models. Confirm the selected electrical version, supply voltage, load current, wiring, and application target with XSZ before order.

  • Factory Direct Supply
    Stable Quality
  • Custom Options
    Support OEM/ODM
  • Technical Support
    Quick Response
Category:

Description

M8 magnetic proximity switch range

The XSZ M8 magnetic proximity switch range is specified around a magnet target rather than an unmagnetized metal part. Its 10 mm ±10% sensing-distance reference is stated against a Ø8 × 2 mm standard magnet, with a separate 0–8 mm setting-distance reference.

The range includes shielded M8 construction and three listed two-wire model codes. Select the exact electrical version for the controller and supply; the NO, NC and AC choices are different models, not settings on one switch.

Body designationM8, shielded
Sensing-distance reference10 mm ±10%
Setting-distance reference0–8 mm
Standard targetØ8 × 2 mm magnet

Match the magnet and switching point

The 10 mm figure is the listed sensing distance under the stated standard-target condition; 0–8 mm is the separate setting-distance range. These are not interchangeable measurements. The magnet’s size, strength, orientation and travel path can affect the actual switching point.

For a moving magnet on a mechanism, check the available M8 mounting space and measure the required switching position in the intended installation. Do not use the nominal sensing-distance figure alone as a clearance guarantee.

Technical specifications for the M8 range

These are range-level figures. Electrical limits and wiring must be checked against the selected model code before installation, especially because the range contains both DC and AC two-wire versions.

Sensing and construction

Body size / shieldingM8 / shielded
Sensing distance10 mm ±10% with the specified standard magnet
Setting distance0–8 mm
Standard detection targetØ8 × 2 mm magnet
HysteresisLess than 10% of sensing distance
Housing / sensing faceNickel-plated brass / ABS
Protection ratingIP67 (IEC), range-level specification

Electrical and environmental references

Continuous load current50 mA in the M8 selection table; verify for the selected code
Operating and storage temperature−30 to +65 °C; no freezing or condensation
Operating and storage humidity35–95% RH
Insulation resistanceAt least 50 MΩ at 500 VDC, between energized parts and housing
Dielectric withstand1000 VAC, 50/60 Hz for 1 minute, between energized parts and housing
Temperature influenceSensing-distance variation within ±15% from −30 to +65 °C, or within ±10% from −25 to +60 °C, compared with +23 °C

Check the selected model’s rated supply voltage, allowable load, response frequency and wiring diagram before connecting power. DC and AC two-wire versions require their respective electrical specifications.

Listed M8 two-wire model codes

The M8 range lists three distinct codes. A chosen unit has one specified output configuration; it does not change between these modes in service.

Electrical versionLogicModel code
DC two-wireNOLG8A3-10-Z/EX
DC two-wireNCLG8A3-10-Z/DX
AC two-wireNOLG8A3-10-J/EZ

Application and installation checks

This range can be evaluated for detecting the position or passage of a magnet-equipped moving part. The actual switching point depends on the chosen magnet and installation, so test with the final target and mounting arrangement.

Before choosing a model

  • Confirm the magnet’s dimensions, orientation and path relative to the M8 sensing face.
  • Select DC two-wire NO, DC two-wire NC or AC two-wire NO to match the controller.
  • Obtain the exact model’s supply, allowable continuous load, response-frequency and wiring details.
  • Check the body drawing, cable exit, mounting clearance and environmental conditions.

Frequently asked questions

Is the 10 mm distance guaranteed with any magnet?

No. The range lists a Ø8 × 2 mm magnet as the standard target. Confirm the actual switching distance with the magnet, orientation and installation you will use.

What is the difference between sensing and setting distance?

The specification gives a 10 mm ±10% sensing-distance reference and a separate 0–8 mm setting-distance range. Use the setting range to plan the intended switch position, then verify it in the installation.

Which output versions are listed?

The listed codes cover DC two-wire NO, DC two-wire NC and AC two-wire NO. Each code is a separate model.

What must be checked before wiring?

Confirm the exact model’s supply voltage, output logic, load limit and wiring diagram. Do not apply the DC wiring notation to the AC code without its own diagram.

Reviews

There are no reviews yet.

Be the first to review “M8 10 mm Magnetic Proximity Switch”

Your email address will not be published. Required fields are marked *