Description
LG-MS series overview
The XSZ LG-MS series covers compact inductive proximity sensors in six housing layouts, MS-1 through MS-6. The supplied drawings show different plan dimensions and mounting-hole references so the mechanical layout can be checked against the available installation space.
The available information identifies magnetic metal as the reference detection target and notes a reduced sensing distance for non-magnetic metal. It does not assign a sensing distance, electrical model code or wiring configuration to each housing. Select an orderable configuration only after those details are confirmed.
Inductive detection and target material
LG-MS uses inductive sensing for magnetic-metal targets. A non-magnetic metal target may be detected at a shorter distance, but no reduction factor or sensing-distance value is provided for a particular MS housing.
Before choosing a sensor, identify the actual target material, size and travel path. Request the sensing-distance data for the selected electrical model and test the target in the intended mounting arrangement.
MS-1 to MS-6 housing dimensions
These are drawing-listed plan dimensions, hole-center spacings and hole callouts. The callouts are preserved as drawing notation; confirm the current mechanical drawing before making a mounting bracket.
| Housing | Plan dimensions | Hole-center spacing | Drawing hole callout |
|---|---|---|---|
| MS-1 | 23 × 14 mm | 14 mm | 2-φ 3.2 × 4 |
| MS-2 | 24 × 16.5 mm | 14 mm | 2-φ 3.2 × 4 |
| MS-3 | 25 × 15 mm | 14 mm | 2-φ 3.2 × 5 |
| MS-4 | 28.5 × 19 mm | 14.5 mm | 2-φ 3.2 × 7 |
| MS-5 | 32.5 × 15.5 mm | 17.5 mm | 2-φ 4 × 8.5 |
| MS-6 | 56 × 21 mm | 39 mm | 2-φ 3.2 × 7 |
Series-listed technical specifications
The available specifications group electrical figures by N/P/D/A type rather than by a complete orderable part number. Verify the selected model and its current datasheet before applying a type-specific rating.
Detection and mechanical data
| Sensing method | Inductive |
|---|---|
| Reference target | Magnetic metal; reduced sensing distance for non-magnetic metal |
| Hysteresis | Less than 10% of sensing distance |
| Sensing distance | Not specified for each housing in the supplied data |
| Housing material | ABS, as listed for the series |
Supply and output by source type
| Listed type | Consumption | Control output |
|---|---|---|
| N/P | Less than 13 mA | Up to 300 mA |
| D | Less than 0.8 mA | Up to 200 mA |
| A | Less than 1.7 mA | Up to 400 mA |
The listed DC voltage notation is 12–24 V (6–36 V), with ripple below 10% peak-to-peak. The AC notation is 110–220 V (36–250 V), 50/60 Hz. The parenthetical ranges need clarification; confirm the exact supply and wiring for the chosen model.
Protection and operating environment
| N/P/D circuit protection | Reverse-connection protection, surge absorption and load short-circuit protection |
|---|---|
| A circuit protection | Surge absorption |
| Operating and storage temperature | −30 to +65 °C; no freezing or condensation |
| Operating and storage humidity | 35–95% RH |
| Insulation resistance | At least 50 MΩ at DC 500 V, between energized parts and housing |
| Withstand voltage | AC 1000 V, 50/60 Hz for 1 minute, between energized parts and housing |
The available information does not specify an IP protection class, cable or connector, or a housing-to-electrical-model mapping. Confirm these for the selected variant.
Applications and installation checks
Suitable evaluation points
- Metal-part presence checks where the actual target can be tested at the required distance.
- Compact machine assemblies where an MS housing matches the available mounting footprint.
- Equipment designs that need a confirmed DC or AC electrical interface and a defined mounting pattern.
Before finalizing a design
Choose an MS housing from the drawing data, then verify its full dimensions and hole details. Check the target material, required sensing distance, chosen electrical type, output logic, supply, wiring, cable route and environmental protection against the exact orderable model. The available series data alone does not establish those mappings.
Frequently asked questions
Does LG-MS refer to one fixed housing?
No. The series information lists six layouts, MS-1 through MS-6. Confirm the exact orderable code for the housing and electrical configuration you need.
Is a sensing distance available for every MS housing?
Not in the supplied table. Request the current sensing-distance data for the selected model and target material.
Can non-magnetic metal be detected?
The series data notes a reduced sensing distance for non-magnetic metal. It gives no reduction factor, so evaluate the actual target and distance before selection.
What information is needed to select a configuration?
Provide the target material and size, required sensing distance, available mounting space, supply, controller input, desired output logic and cable requirements.








Reviews
There are no reviews yet.