Description
SZC-M12-2DN at a glance
The XSZ SZC-M12-2DN is the shielded M12, DC NPN normally open (NO) proximity-sensor selection in the supplied model matrix. Its listed sensing distance is 2 mm ±10%, with a 0–1.7 mm setting-distance range and a 500 Hz response frequency.
This exact code is the 2 mm shielded version. The 5 mm non-shielded options and PNP/NC outputs have separate model codes; they are not settings that can be switched on SZC-M12-2DN. Verify the actual target material and installation gap before specifying it.
| Exact model | SZC-M12-2DN |
|---|---|
| Body / installation | M12, shielded |
| Sensing / setting | 2 mm ±10% / 0–1.7 mm |
| Output | DC NPN NO |
Planning the 2 mm shielded sensing point
The listed 2 mm sensing distance and 0–1.7 mm setting range refer to different limits. Place the actual target within a tested operating gap, allowing for movement, mounting tolerance and the sensor’s switching hysteresis.
An M12 shielded format can suit a compact machine station where the selected output must be NPN normally open. Check target compatibility and the complete mounting drawing, including the sensing-face position and cable exit, before installation.
Technical specifications
Sensing and mechanical data
| Body designation | M12; 12 mm body diameter |
|---|---|
| Body length listed | 60 mm |
| Installation type | Shielded |
| Sensing distance | 2 mm ±10% |
| Setting distance | 0–1.7 mm |
| Response frequency | 500 Hz |
| Switching hysteresis | Less than 15% of rated sensing distance (Sr) |
| Housing material | Nickel-plated copper |
| Sensing face | ABS |
Electrical data for SZC-M12-2DN
| Output configuration | DC NPN, normally open (NO) |
|---|---|
| Operating voltage | 10–30 VDC |
| Supply ripple | Less than 10%, as listed |
| Leakage current | Less than 0.01 mA |
| Voltage drop | Less than 1.5 V |
| Indication | LED |
| Circuit protection | Short-circuit protection listed |
Operating environment
| Protection class | IP65 |
|---|---|
| Operating temperature | 0 to +60 °C |
| Temperature drift | Less than 10% of rated sensing distance (Sr) |
The supplied reference does not resolve the no-load and maximum-load current values or show the final cable/connector wiring. Confirm both before connecting a controller or load.
Related M12 model selections
SZC-M12-2DN is the shielded NPN NO product described here. The codes below identify separate shielding and output selections; they do not change this unit’s detection distance or output logic.
| Mounting / distance | Output | Model code |
|---|---|---|
| Shielded, 2 mm | NPN NO | SZC-M12-2DN — this product |
| Shielded, 2 mm | NPN NC | SZC-M12-2DN2 |
| Shielded, 2 mm | PNP NO | SZC-M12-2DP |
| Shielded, 2 mm | PNP NC | SZC-M12-2DP2 |
| Non-shielded, 5 mm | NPN NO | SZC-M12-5DN |
| Non-shielded, 5 mm | NPN NC | SZC-M12-5DN2 |
| Non-shielded, 5 mm | PNP NO | SZC-M12-5DP |
| Non-shielded, 5 mm | PNP NC | SZC-M12-5DP2 |
Installation and selection checks
This M12 NPN NO sensor can be evaluated for a short-gap presence or position check when the actual target is compatible. Confirm the target material and its behavior at the planned 0–1.7 mm setting distance rather than assuming the nominal 2 mm sensing limit applies to every material.
Before specifying SZC-M12-2DN
- Test the actual target’s material, size and travel against the planned sensing gap.
- Confirm the M12 mounting drawing and the complete cable/connector configuration.
- Match the 10–30 VDC supply and NPN NO output to the controller using a verified wiring diagram.
- Obtain the exact no-load and maximum-load current ratings before selecting the connected load.
Frequently asked questions
Is 2 mm the setting distance?
No. The source lists a 2 mm ±10% sensing distance for this shielded model and a separate 0–1.7 mm setting-distance range.
Is SZC-M12-2DN an NPN normally open version?
Yes. The supplied M12 matrix maps this code to the shielded DC NPN NO selection.
Can it be set to the 5 mm non-shielded range?
No. The 5 mm non-shielded versions have separate model codes; they are not settings on this 2 mm shielded sensor.
What needs confirmation before connection?
Verify the target material, exact current ratings, cable/connector wiring and the controller input for the NPN NO output.






Reviews