LJC18A3-B-Z/BX M18 10 mm Non-shielded Proximity Sensor

The XSZ LJC18A3-B-Z/BX is an M18 x 1 non-shielded proximity sensor with NPN normally open output and a 10 mm +/-10% sensing distance. The supplied non-shielded table also lists NPN NC, PNP NO, PNP NC, AC two-wire NO, and AC two-wire NC models. The non-shielded drawing marks 68 mm and 58 mm length references, a 10 mm sensing-end reference, two clamp nuts, two buckle washers, and a red action display light. Confirm cable and wiring with XSZ before order.

  • Factory Direct Supply
    Stable Quality
  • Custom Options
    Support OEM/ODM
  • Technical Support
    Quick Response

Description

LJC18A3-B-Z/BX at a glance

The XSZ LJC18A3-B-Z/BX is the M18 non-shielded, DC NPN normally open (NO) proximity-sensor model in the supplied 10 mm group. Its listed sensing distance is 10 mm ±10%, with a 0–8 mm setting-distance range. These are different figures: use the setting range when planning the operating gap.

The 10 mm figure is listed alongside a 50 × 50 × 1 mm iron standard-target reference. Check performance with the actual target material, size and approach before finalizing the installation.

Exact modelLJC18A3-B-Z/BX
Body and installationM18, non-shielded
Sensing / setting10 mm ±10% / 0–8 mm
OutputDC NPN NO

Planning a 10 mm non-shielded sensing point

The non-shielded M18 format and 0–8 mm setting-distance range are the starting points for placing this sensor. The listed 50 × 50 × 1 mm iron target is a reference condition, not a promise of the same distance for every workpiece.

Compare the actual target’s material, dimensions and travel path with the reference conditions. Allow space around the non-shielded sensing end, and use the approved mechanical drawing for the final thread engagement, sensor length and cable exit.

Technical specifications

Sensing and construction

Body designationM18
Installation styleNon-shielded
Sensing distance10 mm ±10%
Setting distance0–8 mm
Standard-target reference50 × 50 × 1 mm iron
HysteresisLess than 10% of sensing distance
Thread shown in source drawingM18 × 1; verify against current drawing
Housing / sensing faceNickel-plated brass / ABS
Action indicationRed indicator, as noted in the supplied drawing description

Electrical data for the DC NPN model

Output configurationDC NPN, normally open (NO)
DC supply shown12–24 VDC (6–36 V also listed; confirm rated and allowable ranges)
Supply rippleLess than 10% peak-to-peak
Consumption currentLess than 13 mA (source N.P-type entry)
Control-output entryLess than 300 mA (source N.P-type entry; confirm load-current meaning)
Response frequency0.5 kHz for DC type
Circuit protection shownReverse-connection protection, surge absorption and load short-circuit protection (source N.P.D-type entry)

Environment and electrical insulation

Operating and storage temperature−30 to +65 °C; no freezing or condensation
Operating and storage humidity35–95% RH
Insulation resistanceAt least 50 MΩ at 500 VDC, between energized parts and housing
Temperature influence−30 to +65 °C: within ±15% of the +23 °C sensing-distance reference; −25 to +60 °C: within ±10% of that reference
Voltage influenceSource lists ±15% across the rated voltage range and ±10% sensing-distance influence at rated voltage; verify test wording
Protection classIP67

Related M18 non-shielded model codes

LJC18A3-B-Z/BX is the DC NPN NO model described above. The following codes are separate output or supply selections, not settings that can be changed on this unit. AC-type ratings do not apply to the BX code.

Electrical typeLogicModel code
DC NPNNOLJC18A3-B-Z/BX — this product
DC NPNNCLJC18A3-B-Z/AX
DC PNPNOLJC18A3-B-Z/BY
DC PNPNCLJC18A3-B-Z/AY
AC two-wireNOLJC18A3-B-J/EZ
AC two-wireNCLJC18A3-B-J/DZ

Installation and selection checks

Use this code where the controller requires a DC NPN normally open signal, then validate the sensing response with the actual part at the intended gap. The listed reference target and 0–8 mm setting range should guide the first layout check, not replace an application test.

Before finalizing LJC18A3-B-Z/BX

  • Confirm the actual target material, size, travel and required sensing gap.
  • Match the verified DC supply and NPN NO output to the controller input and load.
  • Check the current drawing for complete dimensions, mounting clearance, cable exit and wiring.
  • Review the operating temperature, humidity and protection requirements for the installation.

Frequently asked questions

Is LJC18A3-B-Z/BX the NPN normally open model?

Yes. The supplied model matrix identifies this exact code as DC NPN NO. The NPN NC, PNP and AC two-wire selections have different model codes.

Is 10 mm the recommended mounting gap?

No. The listed sensing distance is 10 mm ±10%, while the setting-distance range is 0–8 mm. Test the real target before fixing the gap.

Does the listed distance apply to every material?

The supplied specification uses a 50 × 50 × 1 mm iron reference target. Response to the actual material and geometry must be checked separately.

What must be checked before wiring?

Confirm the final DC voltage range, allowable output load, cable or connector arrangement and complete wiring diagram for this exact code.

Reviews

There are no reviews yet.

Be the first to review “LJC18A3-B-Z/BX M18 10 mm Non-shielded Proximity Sensor”

Your email address will not be published. Required fields are marked *