Professional Industrial Sensor Manufacturer
XSZ Sensor
Housing & Thread Size for Your Installation

Match a sensor's body, mounting thread and cable exit to your equipment constraints and installation environment.

Start with the Installation Space

Consider the key installation constraints where your sensor will be mounted.

Mounting hole

Match the mounting hole size and thread type on your equipment.

Available depth

Check the space behind the mounting surface for sensor length and clearance.

Target position

Determine the sensing direction and position relative to the target and machine structure.

Cable exit clearance

Ensure enough space for the cable exit direction and bending radius.

Explore Housing Formats
  • Threaded Cylindrical

    Flexible mounting through a matching threaded hole.

  • Compact Housing

    For restricted machine space.

  • Rectangular Housing

    For mounting surfaces and aligned sensing.

Compare Common Thread Sizes

Review key points for each thread size to ensure a proper fit in your installation.

Housing /
Thread
What to ConfirmInstallation Considerations
M8 × 1Mounting space, target size, required sensing rangeBest where installation space is limited. Confirm mounting hole/bracket compatibility and leave clearance for cable or connector.
M12 × 1Available mounting space, sensing distance, flush/non-flush typeA common compact size. Check mounting nuts, target alignment and cable/connector access.
M18 × 1Required sensing range, target size and surrounding structureAllow sufficient clearance around the sensor body and mounting hardware. Follow the specified flush/non-flush mounting distance.
M30 × 1.5Longer sensing requirement and available installation areaRequires more mounting space. Check surrounding metal clearance, mounting nuts and cable/connector direction.
Which Housing Details Can Be Adjusted?

These housing details can be reviewed for customization to better fit your installation environment.

  • Body Length

    Adjust the overall body length to fit your available installation space.

  • Threaded Section

    Select thread size and thread type to match your mounting hole.

  • Sensing Face

    Review the sensing face design for your target, mounting and protection needs.

  • Mounting Method

    Choose the mounting hardware and method to match your machine structure.

  • Cable Exit Direction

    Set the cable exit direction to avoid interference and fit your cable routing.

  • Material & Protection Needs

    Select suitable housing material and surface treatment for your environmental conditions.

Options are reviewed against the required sensor design and application.

Standard Fit or Custom Fit?

Choose the best way to meet your installation and application needs.

Choose an Existing Model

A standard model is a good fit when your installation and requirements match our available options.

  • Installation space and thread size match
  • Mounting method and cable exit direction fit
  • Electrical requirements are compatible
Request a Housing Adjustment

A customized housing can help when your installation environment needs special consideration.

  • Review space or interference issues
  • Adjust body length, thread or cable exit direction
  • Adapt to mounting structure or orientation needs

The installation drawing and a sample help confirm the right path.

What to Send for a Housing Review

Share your installation information, photos or drawings, and tell us your application requirements. This helps us recommend the right housing and thread size for your sensor.

Current sensor model or drawing

Provide the current model, a drawing or clear photos of your sensor.

Sensing face position

Indicate the sensing face location relative to the mounting surface.

Mounting hole and thread

Specify the mounting hole size and thread type.

Cable routing and exit

Tell us the cable exit direction and required bending space.

Available body length

Let us know the installation space and available length.

Operating environment

Describe temperature, dust, water, chemicals or other conditions.

Target distance and orientation

Share the target position, sensing distance and mounting orientation.

Estimated quantity

Let us know your estimated quantity for planning and support.

From Drawing to Verified Fit

We review your information and work with you to confirm a housing solution that fits your installation.

1. Review Dimensions

Check your drawing, photos and installation requirements.

2. Check Feasibility

Evaluate the housing and thread options for your application.

3. Confirm Structure

Finalize the housing details including length, thread type, sensing face and cable exit.

4. Prepare Sample

Produce a sample based on the confirmed design.

5. Test on Equipment

You test the sample on your equipment to verify the fit and performance.

6. Approve Specification

Confirm the final specification for your production or purchasing plan.

Housing & Thread Size FAQs

Find quick answers to common questions about customization and installation.

Is the same thread size enough to replace an existing sensor?

Thread size alone is not enough. Check body length, sensing face position, mounting clearance, output and cable exit before replacement.

Can the sensor body length be changed?

Body length changes can be reviewed for the selected model. Feasibility depends on the sensing principle, internal components, housing structure and mounting requirements. Share the available space and required dimensions so xsz sensor can review the options before a sample is prepared.

What if the mounting hole cannot be modified?

Provide the hole diameter or thread designation, thread pitch, mounting plate thickness and surrounding clearance. We can review a housing or mounting arrangement within those constraints. Matching the hole does not by itself confirm the sensing position, electrical compatibility or installation fit.

Do you need my current sensor or installation drawing?

A model number, dimensioned drawing and clear installation photos are useful starting points. Include the thread specification, body length, sensing face position, cable exit and target location. If important dimensions remain unclear, a physical sample may be requested as part of the agreed review.

How do I verify the sample on my equipment?

Check the sample against the agreed drawing, then verify mounting fit, sensing face alignment, cable routing and clearance through the machine's motion. Test detection and output with the actual target under normal operating conditions. Record the results and confirm any changes before approving the production specification.