Match the mounting hole size and thread type on your equipment.
Match a sensor's body, mounting thread and cable exit to your equipment constraints and installation environment.
Consider the key installation constraints where your sensor will be mounted.
Match the mounting hole size and thread type on your equipment.
Check the space behind the mounting surface for sensor length and clearance.
Determine the sensing direction and position relative to the target and machine structure.
Ensure enough space for the cable exit direction and bending radius.
Flexible mounting through a matching threaded hole.
For restricted machine space.
For mounting surfaces and aligned sensing.
Review key points for each thread size to ensure a proper fit in your installation.
| Housing / Thread | What to Confirm | Installation Considerations |
|---|---|---|
| M8 × 1 | Mounting space, target size, required sensing range | Best where installation space is limited. Confirm mounting hole/bracket compatibility and leave clearance for cable or connector. |
| M12 × 1 | Available mounting space, sensing distance, flush/non-flush type | A common compact size. Check mounting nuts, target alignment and cable/connector access. |
| M18 × 1 | Required sensing range, target size and surrounding structure | Allow sufficient clearance around the sensor body and mounting hardware. Follow the specified flush/non-flush mounting distance. |
| M30 × 1.5 | Longer sensing requirement and available installation area | Requires more mounting space. Check surrounding metal clearance, mounting nuts and cable/connector direction. |
These housing details can be reviewed for customization to better fit your installation environment.
Adjust the overall body length to fit your available installation space.
Select thread size and thread type to match your mounting hole.
Review the sensing face design for your target, mounting and protection needs.
Choose the mounting hardware and method to match your machine structure.
Set the cable exit direction to avoid interference and fit your cable routing.
Select suitable housing material and surface treatment for your environmental conditions.
Options are reviewed against the required sensor design and application.
Choose the best way to meet your installation and application needs.
A standard model is a good fit when your installation and requirements match our available options.
A customized housing can help when your installation environment needs special consideration.
The installation drawing and a sample help confirm the right path.
Share your installation information, photos or drawings, and tell us your application requirements. This helps us recommend the right housing and thread size for your sensor.
Provide the current model, a drawing or clear photos of your sensor.
Indicate the sensing face location relative to the mounting surface.
Specify the mounting hole size and thread type.
Tell us the cable exit direction and required bending space.
Let us know the installation space and available length.
Describe temperature, dust, water, chemicals or other conditions.
Share the target position, sensing distance and mounting orientation.
Let us know your estimated quantity for planning and support.
We review your information and work with you to confirm a housing solution that fits your installation.
Check your drawing, photos and installation requirements.
Evaluate the housing and thread options for your application.
Finalize the housing details including length, thread type, sensing face and cable exit.
Produce a sample based on the confirmed design.
You test the sample on your equipment to verify the fit and performance.
Confirm the final specification for your production or purchasing plan.
Find quick answers to common questions about customization and installation.
Thread size alone is not enough. Check body length, sensing face position, mounting clearance, output and cable exit before replacement.
Body length changes can be reviewed for the selected model. Feasibility depends on the sensing principle, internal components, housing structure and mounting requirements. Share the available space and required dimensions so xsz sensor can review the options before a sample is prepared.
Provide the hole diameter or thread designation, thread pitch, mounting plate thickness and surrounding clearance. We can review a housing or mounting arrangement within those constraints. Matching the hole does not by itself confirm the sensing position, electrical compatibility or installation fit.
A model number, dimensioned drawing and clear installation photos are useful starting points. Include the thread specification, body length, sensing face position, cable exit and target location. If important dimensions remain unclear, a physical sample may be requested as part of the agreed review.
Check the sample against the agreed drawing, then verify mounting fit, sensing face alignment, cable routing and clearance through the machine's motion. Test detection and output with the actual target under normal operating conditions. Record the results and confirm any changes before approving the production specification.
Tell us your mounting constraints and detection requirements to begin a feasibility review.