Description
LJ12A3-4-Z/BX product overview
The XSZ LJ12A3-4-Z/BX is a non-shielded inductive proximity sensor with a DC NPN normally open (NO) output. The listed sensing distance is 4 mm ±10%, with a setting-distance range of 0–3.6 mm under the supplied reference conditions.
The standard detection target is iron measuring 15 × 15 × 1 mm. Detection distance decreases for non-magnetic metals, so confirm the actual target material, size and mounting arrangement before finalizing the sensor position.
4 mm non-shielded metal detection
The 4 mm value is a sensing-distance specification, not the diameter of the sensor. The product table identifies its dimension class as M12. The full body length and installation clearances are not stated in the available information; use the current mechanical drawing for mounting design.
The 0–3.6 mm setting range gives a separate installation reference. Check target variation, sensor-to-target alignment and nearby metal against the actual application before setting a switching point.
Technical specifications
The following values are listed in the available product information. Confirm the latest LJ12A3-4-Z/BX datasheet and wiring diagram before using them as installation or controller-design limits.
Sensing and construction
| Sensing method and mounting type | Inductive, non-shielded |
|---|---|
| Dimension designation | M12; full mechanical dimensions to confirm |
| Sensing distance | 4 mm ±10% |
| Setting distance | 0–3.6 mm |
| Standard detection target | Iron, 15 × 15 × 1 mm |
| Detectable target | Magnetic metal; shorter sensing distance for non-magnetic metals |
| Hysteresis | Less than 10% of sensing distance |
| Housing / sensing face | Nickel-plated brass / ABS |
| Protection class | IP67 |
NPN NO electrical data
| Output configuration | DC NPN, normally open (NO) |
|---|---|
| DC supply notation | DC 12–24 V (6–36 V); confirm the meaning of both ranges |
| Supply ripple | Less than 10% peak-to-peak |
| N/P-type consumption current | Less than 13 mA |
| N/P-type control output | Less than 300 mA |
| DC response frequency | 0.5 kHz |
| N/P/D-type circuit protection | Reverse-connection protection, surge absorption and load short-circuit protection |
Operating environment and insulation
| Operating and storage temperature | −30 to +65 °C; no freezing or condensation |
|---|---|
| Operating and storage humidity | 35–95% RH |
| Insulation resistance | At least 50 MΩ at DC 500 V, between energized parts and housing |
The supplied temperature-influence entries refer to sensing-distance change relative to +23 °C: within ±15% over −30 to +65 °C and within ±10% over −25 to +60 °C. Confirm the test basis and the separate voltage-influence wording against the current datasheet before treating either as a design limit.
Related non-shielded 4 mm models
LJ12A3-4-Z/BX is the DC NPN NO sensor described on this page. The following codes are separate electrical and output selections, not modes that can be changed on this unit. The AC two-wire choices have a different supply category.
| Electrical type | Output | Logic | Model |
|---|---|---|---|
| DC | NPN | NO | LJ12A3-4-Z/BX — this product |
| DC | NPN | NC | LJ12A3-4-Z/AX |
| DC | NPN | NO+NC | LJ12A3-4-Z/CX |
| DC | PNP | NO | LJ12A3-4-Z/BY |
| DC | PNP | NC | LJ12A3-4-Z/AY |
| DC | PNP | NO+NC | LJ12A3-4-Z/CY |
| DC | Two-wire | NO | LJ12A3-4-Z/EX |
| DC | Two-wire | NC | LJ12A3-4-Z/DX |
| AC | Two-wire | NO | LJ12A3-4-J/EZ |
| AC | Two-wire | NC | LJ12A3-4-J/DZ |
Confirm the exact supply, load and wiring for any alternative model. The source lists AC 110–220 V (36–250 V), 50/60 Hz and 25 Hz response for the separate AC types; these are not specifications for LJ12A3-4-Z/BX.
Applications and installation checks
Potential applications
- Detecting a defined iron or other magnetic-metal target at a repeatable machine position.
- Providing an NPN NO signal to a compatible DC controller input after the load and wiring are checked.
- Monitoring a metal part in compact equipment where the M12 designation fits the mechanical design.
Before installation or ordering
Confirm the target material, shape, travel variation and working gap against the 0–3.6 mm setting range. Obtain the current M12 body drawing for full length and non-shielded mounting clearance. Check the DC supply notation, controller input, load current, cable or connector and wiring diagram for the `/BX` model. The supplied source does not specify cable length or connection colors.
Frequently asked questions
Is LJ12A3-4-Z/BX NPN or PNP?
The supplied model matrix identifies `/BX` as the DC NPN normally open option. PNP and other output configurations have different part numbers.
How do the 4 mm and 0–3.6 mm figures differ?
The first is the listed sensing distance with ±10% tolerance; the second is the setting-distance range. Check both against the actual target and installation conditions.
Will it sense non-magnetic metals at 4 mm?
The available data says sensing distance decreases for non-magnetic metals but does not give a correction factor. Verify the chosen target and working gap.
What mechanical and electrical details remain to be confirmed?
Confirm the full M12 drawing, non-shielded mounting clearance, the DC supply ranges, cable or connector, wiring diagram and controller load compatibility for `/BX`.








Reviews
There are no reviews yet.