Description
LJ30A3-10-Z/BX product overview
The XSZ LJ30A3-10-Z/BX is the M30 shielded, DC NPN normally open (NO) model in the listed 10 mm proximity-sensor range. It is intended for detecting a metal target at a defined sensing point; the supplied specifications use an iron 30 × 30 × 1 mm target as the standard reference.
Its listed sensing distance is 10 mm ±10%, while the setting distance is 0–8 mm. The operating gap should be selected around the actual target material, size, position and machine movement rather than treating 10 mm as a guaranteed distance for every metal part.
| Model | LJ30A3-10-Z/BX |
|---|---|
| Body size designation | M30 |
| Sensing distance | 10 mm ±10% |
| Output | DC NPN, normally open |
10 mm shielded sensing for metal targets
The 10 mm figure is the listed sensing distance, not a target diameter. The separate 0–8 mm setting distance provides the installation range stated by the source. The reference target is an iron plate measuring 30 × 30 × 1 mm.
The supplied data says the sensing distance decreases for non-magnetic metals. When the real part is a different material, smaller than the standard target or presented at a different angle, verify detection at the actual installation gap. Select LJ30A3-10-Z/BX only when its NPN NO output matches the controller input.
Technical specifications
The values below are taken from the supplied LJ30A3 shielded-series material. Confirm the current model drawing and wiring sheet when specifying the unit for a machine.
Detection and construction
| Sensing configuration | Shielded |
|---|---|
| Body size designation | M30; overall dimensions are not stated in the supplied material |
| Sensing distance | 10 mm ±10% |
| Setting distance | 0–8 mm |
| Standard detection target | Iron 30 × 30 × 1 mm |
| Detectable target note | Magnetic metal; listed sensing distance decreases for non-magnetic metals |
| Hysteresis | Less than 10% of sensing distance |
| Housing | Nickel-plated brass |
| Sensing face | ABS |
Electrical performance for the DC NPN NO selection
| Output configuration | DC NPN, normally open (NO) |
|---|---|
| Listed DC supply | 12–24 VDC nominal; 6–36 VDC listed range |
| Supply ripple | Less than 10% peak to peak, as listed |
| DC response frequency | 0.5 kHz, as listed for DC type |
| Cable and wiring | Confirm the cable specification and current wiring diagram for this model |
Environment and insulation
| Operating and storage temperature | −30 to +65 °C; no freezing or condensation |
|---|---|
| Operating and storage humidity | 35–95% RH |
| Insulation resistance | At least 50 MΩ at 500 VDC, between energized parts and housing |
| Protection class | IP67 |
Related M30 shielded models
LJ30A3-10-Z/BX is the NPN NO product described here. The codes below are separate models from the supplied series matrix. Their output types are not switchable settings on this unit; confirm availability and individual ratings before ordering another code.
| Electrical type | Output | Logic | Model code |
|---|---|---|---|
| DC | NPN | NO | LJ30A3-10-Z/BX — this product |
| DC | NPN | NC | LJ30A3-10-Z/AX |
| DC | NPN | NO + NC | LJ30A3-10-Z/CX |
| DC | PNP | NO | LJ30A3-10-Z/BY |
| DC | PNP | NC | LJ30A3-10-Z/AY |
| DC | PNP | NO + NC | LJ30A3-10-Z/CY |
| DC | 2-wire | NO | LJ30A3-10-Z/EX |
| DC | 2-wire | NC | LJ30A3-10-Z/DX |
| AC | 2-wire | NO | LJ30A3-10-J/EZ |
| AC | 2-wire | NC | LJ30A3-10-J/DZ |
Application and installation checks
This model can be evaluated for a fixed metal-target detection point in an automated machine when an M30 shielded body and an NPN NO signal suit the station. The real target and mounting geometry determine whether the listed sensing and setting distances are suitable.
Before specifying LJ30A3-10-Z/BX
- Check the target material, dimensions and position against the iron 30 × 30 × 1 mm reference and the 0–8 mm setting distance.
- Match the DC supply, NPN NO controller input and required response timing to the current wiring data.
- Confirm the M30 mounting fit, overall body dimensions, cable type and cable-exit clearance using the current drawing.
- Check temperature, humidity and exposure conditions against the listed environmental ratings.
Frequently asked questions
Is LJ30A3-10-Z/BX the NPN normally open model?
Yes. The supplied shielded-series matrix identifies this exact code as the DC NPN NO option. PNP, NC and two-wire choices have different model codes.
What is the difference between sensing and setting distance?
The listed sensing distance is 10 mm ±10%; the specified setting distance is 0–8 mm. Use the setting range for installation planning and verify detection with the actual target.
Will the 10 mm distance apply to every metal?
No. The reference target is iron 30 × 30 × 1 mm, and the source says sensing distance decreases for non-magnetic metals. Confirm the real part’s material, size and presentation.
What must be checked before wiring the sensor?
Confirm the current BX wiring diagram, cable configuration, DC supply and controller input. The supplied material does not specify a cable length or wire-colour diagram.








Reviews
There are no reviews yet.