Description
LJ12A3-2-Z/BX product overview
The XSZ LJ12A3-2-Z/BX is the DC NPN normally open (NO) model in an M12 shielded proximity-sensor range. Its listed sensing distance is 2 mm ±10% against a 12 × 12 × 1 mm iron standard target.
The separate 0–1.6 mm setting-distance reference helps define the intended switching position. If the target is not iron, verify the actual detection distance: the supplied specification states that sensing distance decreases for non-magnetic metals.
| Exact model | LJ12A3-2-Z/BX |
|---|---|
| Body / installation type | M12 / shielded |
| Sensing-distance reference | 2 mm ±10% |
| Output | DC NPN, normally open |
2 mm shielded metal-target detection
This product is selected for a defined metal target passing near the sensing face. The 2 mm ±10% figure is referenced to a 12 × 12 × 1 mm iron target; it should not be treated as the same range for a smaller target or a different metal.
Use the 0–1.6 mm setting-distance reference when planning the nominal switch point, then test the real target’s material, size and approach path in the machine. The NPN NO output must match the controller input and selected wiring arrangement.
LJ12A3-2-Z/BX technical specifications
The electrical and environmental values below come from the supplied M12 shielded range table. Confirm the final BX drawing, power limits, cable and output-load rating before connecting a controller.
Detection and housing
| Body designation | M12 |
|---|---|
| Installation type | Shielded |
| Sensing distance | 2 mm ±10% with the standard iron target |
| Setting distance | 0–1.6 mm |
| Standard detection target | Iron, 12 × 12 × 1 mm |
| Target-material note | Sensing distance decreases for non-magnetic metals |
| Housing / sensing face | Nickel-plated brass / ABS |
| Protection rating | IP67 (range specification) |
DC NPN operation and electrical references
| Output configuration | DC NPN, normally open (NO) |
|---|---|
| DC supply listed for range | 12–24 VDC; confirm the BX model’s permissible operating range |
| Supply ripple | Less than 10% peak-to-peak (DC range table) |
| Consumption-current entry | N/P-type range: less than 13 mA; confirm applicability to BX |
| Control-output entry | N/P-type range: less than 300 mA; confirm the BX model’s permitted continuous load |
| Response frequency | 0.5 kHz (DC-range value) |
| Hysteresis | Less than 10% of sensing distance |
| Protection listed for N/P/D types | Reverse-connection protection, surge absorption and load short-circuit protection; confirm BX coverage |
| Insulation resistance | At least 50 MΩ at 500 VDC, between energized parts and housing (range specification) |
Operating environment and temperature influence
| Operating and storage temperature | −30 to +65 °C; no freezing or condensation |
|---|---|
| Operating and storage humidity | 35–95% RH |
| Temperature influence | Sensing-distance change within ±15% from −30 to +65 °C, or within ±10% from −25 to +60 °C, relative to +23 °C (range specification) |
Related M12 shielded output models
LJ12A3-2-Z/BX is the NPN NO unit described here. The following are separate model codes from the same shielded range, not output modes that can be selected on this unit. AC two-wire electrical ratings must not be applied to BX.
| Electrical type | Logic | Model |
|---|---|---|
| DC NPN | NO | LJ12A3-2-Z/BX — this product |
| DC NPN | NC | LJ12A3-2-Z/AX |
| DC NPN | NO+NC | LJ12A3-2-Z/CX |
| DC PNP | NO | LJ12A3-2-Z/BY |
| DC PNP | NC | LJ12A3-2-Z/AY |
| DC PNP | NO+NC | LJ12A3-2-Z/CY |
| DC two-wire | NO | LJ12A3-2-Z/EX |
| DC two-wire | NC | LJ12A3-2-Z/DX |
| AC two-wire | NO | LJ12A3-2-J/EZ |
| AC two-wire | NC | LJ12A3-2-J/DZ |
Applications and installation checks
Use this sensor to evaluate the presence or position of a metal part near an M12 sensing point. Its shielded form can be considered where the mounting space and target path suit the specified arrangement. Confirm the actual detection gap, especially for a smaller or non-iron target.
Before specifying LJ12A3-2-Z/BX
- Check the target’s material, size, approach path and required operating gap against the iron standard target.
- Confirm the NPN NO controller interface, DC supply and permissible output load.
- Obtain the current M12 drawing, cable or connector details and model-specific wiring diagram.
- Match the machine cycle to a confirmed response-frequency requirement and verify the operating environment.
Frequently asked questions
Is LJ12A3-2-Z/BX NPN normally open?
Yes. The supplied M12 shielded model matrix lists LJ12A3-2-Z/BX as the DC NPN NO model. NC, PNP and two-wire selections have different codes.
Will it detect non-iron metal at the full 2 mm distance?
Do not assume that. The 2 mm reference is based on a 12 × 12 × 1 mm iron target, and the range specification says the sensing distance decreases for non-magnetic metals. Test the intended target.
What is the listed setting distance?
It is 0–1.6 mm, separate from the 2 mm ±10% sensing-distance reference. Verify the switch point with the final target and mounting layout.
Can the AC or PNP specifications be used for this BX model?
No. BX is listed as DC NPN NO. Use the model-specific wiring, supply and output-load specifications rather than another code’s electrical data.