LJ18A3-8-Z/BX 8 mm Non-shielded Proximity Sensor

The XSZ LJ18A3-8-Z/BX is a non-shielded DC proximity sensor with NPN normally open output and an 8 mm +/-10% sensing distance. The supplied non-shielded matrix also lists NPN and PNP NO, NC, and NO+NC options, plus DC two-wire and AC two-wire models. Confirm dimensions, cable, wiring, and target compatibility with XSZ before order.

  • Factory Direct Supply
    Stable Quality
  • Custom Options
    Support OEM/ODM
  • Technical Support
    Quick Response

Description

LJ18A3-8-Z/BX at a glance

The XSZ LJ18A3-8-Z/BX is the non-shielded M18 proximity sensor with an NPN DC, normally open (NO) output. Its listed sensing distance is 8 mm ±10%, with a 0–7 mm setting-distance range and a 30 × 30 × 1 mm iron standard target.

This exact code is the NPN NO selection. PNP, DC two-wire and AC two-wire versions have separate codes; their electrical ratings and connection methods should not be applied to this model.

ModelLJ18A3-8-Z/BX
Body / installationM18, non-shielded
Sensing / setting8 mm ±10% / 0–7 mm
OutputDC NPN NO

8 mm non-shielded metal detection

The 8 mm sensing-distance figure uses a 30 × 30 × 1 mm iron target as its standard reference. For installation, the listed setting-distance range is 0–7 mm, giving room to position the target inside the outer sensing limit.

Magnetic metal is the listed detectable target, with reduced sensing distance for non-magnetic metals. Check the actual workpiece’s material, size, approach direction and movement before finalizing the sensor gap.

Technical specifications

Sensing and mechanical data

Body designationM18
Shielding typeNon-shielded
Sensing distance8 mm ±10%
Setting distance0–7 mm
Standard target30 × 30 × 1 mm iron
Detectable targetMagnetic metal; reduced distance for non-magnetic metals
HysteresisLess than 10% of sensing distance
Housing materialNickel-plated brass
Sensing faceABS

Electrical data for LJ18A3-8-Z/BX

Output configurationDC NPN, normally open (NO)
DC supply listed12–24 VDC (6–36 V also shown; confirm the rated and allowable ranges)
Supply rippleLess than 10% peak-to-peak
Consumption currentLess than 13 mA for N/P type
Control-output entryLess than 300 mA for N/P type; confirm load-current interpretation
Response frequency0.5 kHz for DC type
Circuit protectionReverse-connection protection, surge absorption and load short-circuit protection for N/P/D types

Operating environment and insulation

Operating and storage temperature−30 to +65 °C; no freezing or condensation
Operating and storage humidity35–95% RH
Insulation resistanceAt least 50 MΩ at 500 VDC, between energized parts and housing
Temperature influence−30 to +65 °C: within ±15% of the +23 °C sensing-distance reference; −25 to +60 °C: within ±10% of that reference
Voltage influenceWithin ±15% of rated supply-voltage range; within ±10% sensing distance at rated supply voltage
Protection classIP67

Related non-shielded M18 models

LJ18A3-8-Z/BX is the NPN NO model described here. The following codes are separate electrical and output selections, not modes that can be changed on this unit.

Electrical typeLogicModel code
NPN DCNOLJ18A3-8-Z/BX — this product
NPN DCNCLJ18A3-8-Z/AX
NPN DCNO+NCLJ18A3-8-Z/CX
PNP DCNOLJ18A3-8-Z/BY
PNP DCNCLJ18A3-8-Z/AY
PNP DCNO+NCLJ18A3-8-Z/CY
DC two-wireNOLJ18A3-8-Z/EX
DC two-wireNCLJ18A3-8-Z/DX
AC two-wireNOLJ18A3-8-J/EZ
AC two-wireNCLJ18A3-8-J/DZ

Application and installation checks

This NPN NO model can be evaluated at a metal-target position where the actual workpiece passes the sensing face within the intended 0–7 mm setting range. Verify clearance around the non-shielded sensing area and the final mounting dimensions against the current drawing.

Before specifying LJ18A3-8-Z/BX

  • Test the actual target material, shape, size and travel against the iron reference condition.
  • Check the DC supply and the NPN NO controller input; do not use AC or PNP ratings from the related models.
  • Confirm the selected sensor’s complete wiring diagram, cable/connector choice and load-current limit.
  • Check the M18 mounting details, nearby metal and environmental conditions for the installation.

Frequently asked questions

Is LJ18A3-8-Z/BX the NPN normally open model?

Yes. LJ18A3-8-Z/BX is the DC NPN NO selection. Other output types have separate model codes.

Is 8 mm the setting distance?

No. The listed sensing distance is 8 mm ±10% with the standard iron target, while the setting-distance range is 0–7 mm.

Will it detect non-magnetic metal at 8 mm?

Not necessarily. The listed sensing distance is lower for non-magnetic metals. Test the actual workpiece before setting the operating gap.

What needs checking before connection?

Confirm the selected model’s rated DC voltage, NPN NO controller input, output-current limit and complete wiring diagram.

Reviews

There are no reviews yet.

Be the first to review “LJ18A3-8-Z/BX 8 mm Non-shielded Proximity Sensor”

Your email address will not be published. Required fields are marked *