LJ18A3-8-Z/BX at a glance
The XSZ LJ18A3-8-Z/BX is the non-shielded M18 proximity sensor with an NPN DC, normally open (NO) output. Its listed sensing distance is 8 mm ±10%, with a 0–7 mm setting-distance range and a 30 × 30 × 1 mm iron standard target.
This exact code is the NPN NO selection. PNP, DC two-wire and AC two-wire versions have separate codes; their electrical ratings and connection methods should not be applied to this model.
| Model | LJ18A3-8-Z/BX |
|---|---|
| Body / installation | M18, non-shielded |
| Sensing / setting | 8 mm ±10% / 0–7 mm |
| Output | DC NPN NO |
8 mm non-shielded metal detection
The 8 mm sensing-distance figure uses a 30 × 30 × 1 mm iron target as its standard reference. For installation, the listed setting-distance range is 0–7 mm, giving room to position the target inside the outer sensing limit.
Magnetic metal is the listed detectable target, with reduced sensing distance for non-magnetic metals. Check the actual workpiece’s material, size, approach direction and movement before finalizing the sensor gap.
Technical specifications
Sensing and mechanical data
| Body designation | M18 |
|---|---|
| Shielding type | Non-shielded |
| Sensing distance | 8 mm ±10% |
| Setting distance | 0–7 mm |
| Standard target | 30 × 30 × 1 mm iron |
| Detectable target | Magnetic metal; reduced distance for non-magnetic metals |
| Hysteresis | Less than 10% of sensing distance |
| Housing material | Nickel-plated brass |
| Sensing face | ABS |
Electrical data for LJ18A3-8-Z/BX
| Output configuration | DC NPN, normally open (NO) |
|---|---|
| DC supply listed | 12–24 VDC (6–36 V also shown; confirm the rated and allowable ranges) |
| Supply ripple | Less than 10% peak-to-peak |
| Consumption current | Less than 13 mA for N/P type |
| Control-output entry | Less than 300 mA for N/P type; confirm load-current interpretation |
| Response frequency | 0.5 kHz for DC type |
| Circuit protection | Reverse-connection protection, surge absorption and load short-circuit protection for N/P/D types |
Operating environment and insulation
| Operating and storage temperature | −30 to +65 °C; no freezing or condensation |
|---|---|
| Operating and storage humidity | 35–95% RH |
| Insulation resistance | At least 50 MΩ at 500 VDC, between energized parts and housing |
| Temperature influence | −30 to +65 °C: within ±15% of the +23 °C sensing-distance reference; −25 to +60 °C: within ±10% of that reference |
| Voltage influence | Within ±15% of rated supply-voltage range; within ±10% sensing distance at rated supply voltage |
| Protection class | IP67 |
Related non-shielded M18 models
LJ18A3-8-Z/BX is the NPN NO model described here. The following codes are separate electrical and output selections, not modes that can be changed on this unit.
| Electrical type | Logic | Model code |
|---|---|---|
| NPN DC | NO | LJ18A3-8-Z/BX — this product |
| NPN DC | NC | LJ18A3-8-Z/AX |
| NPN DC | NO+NC | LJ18A3-8-Z/CX |
| PNP DC | NO | LJ18A3-8-Z/BY |
| PNP DC | NC | LJ18A3-8-Z/AY |
| PNP DC | NO+NC | LJ18A3-8-Z/CY |
| DC two-wire | NO | LJ18A3-8-Z/EX |
| DC two-wire | NC | LJ18A3-8-Z/DX |
| AC two-wire | NO | LJ18A3-8-J/EZ |
| AC two-wire | NC | LJ18A3-8-J/DZ |
Application and installation checks
This NPN NO model can be evaluated at a metal-target position where the actual workpiece passes the sensing face within the intended 0–7 mm setting range. Verify clearance around the non-shielded sensing area and the final mounting dimensions against the current drawing.
Before specifying LJ18A3-8-Z/BX
- Test the actual target material, shape, size and travel against the iron reference condition.
- Check the DC supply and the NPN NO controller input; do not use AC or PNP ratings from the related models.
- Confirm the selected sensor’s complete wiring diagram, cable/connector choice and load-current limit.
- Check the M18 mounting details, nearby metal and environmental conditions for the installation.
Frequently asked questions
Is LJ18A3-8-Z/BX the NPN normally open model?
Yes. LJ18A3-8-Z/BX is the DC NPN NO selection. Other output types have separate model codes.
Is 8 mm the setting distance?
No. The listed sensing distance is 8 mm ±10% with the standard iron target, while the setting-distance range is 0–7 mm.
Will it detect non-magnetic metal at 8 mm?
Not necessarily. The listed sensing distance is lower for non-magnetic metals. Test the actual workpiece before setting the operating gap.
What needs checking before connection?
Confirm the selected model’s rated DC voltage, NPN NO controller input, output-current limit and complete wiring diagram.








Reviews
There are no reviews yet.