Description
M5/M6 series overview
The XSZ M5/M6 series covers miniature inductive proximity sensors in M5 and M6 threaded, shielded housings. The available specifications list a 1 mm ±15% sensing-distance reference for metal detection and a 1 kHz response frequency.
The two sizes have different standard iron targets. NPN and PNP outputs, as well as normally open and normally closed logic, are listed as series choices; select an exact orderable model before finalizing the electrical interface.
M5 and M6 target references
The source uses a separate standard iron target for each housing size. Actual detection distance may decrease for non-magnetic metals; no material correction factor is given.
| Housing option | Standard iron target | Mounting entry |
|---|---|---|
| M5 | 5 × 5 × 1 mm | Shielded, flush mount |
| M6 | 8 × 8 × 1 mm | Shielded, flush mount |
The table does not give full body lengths, cable dimensions or model codes. Confirm the drawing for the selected M5 or M6 sensor before designing the mounting point.
Series-listed technical specifications
The following values are presented for the M5/M6 series in the available product information. Confirm their applicability to the chosen orderable model using its current datasheet.
Sensing and mechanical data
| Sensing method | Inductive |
|---|---|
| Housing sizes | M5 or M6 threaded cylindrical options |
| Installation method | Shielded, flush mount |
| Sensing distance | 1 mm ±15%; verify for each size and reference target |
| Detectable object | Magnetic metals; reduced distance for non-magnetic metals |
DC supply and output data
| Supply | DC 10–30 V; 12–24 VDC listed as nominal |
|---|---|
| Ripple | Maximum 10% peak-to-peak |
| Current consumption | Maximum 10 mA |
| Load current | Maximum 100 mA |
| Residual voltage | Maximum 1.5 V |
| Response frequency | 1 kHz as listed; confirm the test conditions for the exact model |
| Control-output options | NPN or PNP; normally open (NO) or normally closed (NC), depending on model |
| Circuit protection | Reverse-supply-polarity protection |
Environment and connection
| Operating temperature | −25 to +70 °C |
|---|---|
| Connection style | Pre-wired cable; length and wiring to confirm |
Applications and installation checks
The M5 and M6 housings can be evaluated for metal-part presence checks where installation space is limited. The 1 kHz series entry may be relevant to moving parts, but the required response should be validated with the actual target, travel speed and selected model before use in a counting or positioning task.
Before selecting a sensor
- Choose the M5 or M6 housing and use its corresponding standard-target reference.
- Confirm the actual target material, size, working gap and flush-mount drawing.
- Match the exact NPN/PNP and NO/NC model to the controller input, supply and load.
- Check body length, cable length, wiring, environmental protection and response under the intended operating conditions.
Frequently asked questions
Is the standard target the same for M5 and M6?
No. The listed iron targets are 5 × 5 × 1 mm for M5 and 8 × 8 × 1 mm for M6. Confirm the sensing distance with the intended target.
Does every M5 or M6 model have both NPN and PNP outputs?
They are listed as series options, not as confirmed switchable outputs on one unit. Select an orderable code with the required output and logic.
Can non-magnetic metal be detected at 1 mm?
The available data says its sensing distance is reduced, but gives no correction factor. Check the actual material and working gap before specifying the sensor.
Which installation details are still needed?
Obtain the exact body drawing, cable and wiring details, mounting arrangement and model-specific environmental rating before finalizing the design.





Reviews