Description
EUSL-U30 L-type dual-channel slot sensing
The EUSL-U30 L-type slot photo sensor series places two independent optical axes in an L-shaped, 30 mm-gap sensing format. Each channel can detect an opaque target passing through its optical path, giving the controller two distinct position signals in one sensor assembly.
The supplied series data lists an opaque target larger than Ø12 mm. Choose the NPN or PNP version to match the control input; these are separate model codes rather than a switchable output setting on one unit.
Two detection channels in an L-shaped layout
The A and B optical axes provide independent detection points. This layout may suit applications that need two position events along the target’s travel, provided the target crosses the required beams and the controller can interpret both outputs.
The shape can help place the sensing paths around a machine feature where straight mounting is difficult. Use the current mounting drawing to confirm the actual clearances, channel positions and direction of target travel; the 30 mm source figure alone does not define every installation dimension.
Technical specifications
The values below are listed in the supplied EUSL-U30 L-type series material. Confirm the selected model’s current drawing and electrical data before installation.
Detection and response
| Detection format | L-type slot photoelectric sensor |
|---|---|
| Gap listed | 30 mm |
| Optical axes | Two independent channels |
| Detectable object | Opaque object larger than Ø12 mm, as listed |
| Operate / reset response | 1 ms maximum |
Power, output and indication
| Supply voltage | 10–30 VDC |
|---|---|
| Output | Open collector; NPN or PNP by model |
| Maximum load current | 100 mA |
| Status indicators | Green circuit indicator; red/yellow A/B channel indicators |
| Circuit protection listed | Reverse supply polarity and instantaneous overvoltage |
Construction and light environment
| Housing / lens | ABS / PC |
|---|---|
| Connection | Pre-wired 2 m cable |
| Ambient sunlight | 10,000 lx maximum, as listed |
Choose the NPN or PNP version
Both codes refer to the L-type arrangement, but their output types differ. Match the selected code to the controller input and use its corresponding wiring diagram.
| Model | Output |
|---|---|
| EUSL-U30R3C4-L | NPN |
| EUSL-U30X3C4-L | PNP |
Application and installation checks
The two-channel layout can be evaluated for position sensing in elevator mechanisms, web/film edge arrangements and automated machinery. These are application examples, not a certification for a safety function. Validate target travel, controller logic and required response using the actual assembly.
Before specifying the L-type model
- Confirm that the opaque target crosses the intended A and B optical paths and meets the source-listed size requirement.
- Check the actual 30 mm gap, channel positions, mounting holes and available machine clearance on the current drawing.
- Select NPN or PNP for the controller and verify both channel connections before energizing.
- Confirm cable routing, sunlight exposure, protection limits and any site-specific environmental requirement.
Frequently asked questions
Are the two optical channels independent?
The supplied series data lists two independent optical axes. Confirm the A/B output sequence and spacing in the selected model’s drawing.
Which model has NPN output?
EUSL-U30R3C4-L is listed as NPN. EUSL-U30X3C4-L is the PNP selection; the output type is not described as switchable on one sensor.
What kind of target is specified?
The supplied specification lists an opaque object larger than Ø12 mm. Verify its orientation and travel through the required optical axes in the actual installation.
Can it be used as an elevator safety device?
This page describes position detection only. No safety rating or certified protective function is established by the available series information.