PR12-4DN M12 4 mm Non-shielded Proximity Sensor

The XSZ PR12-4DN is an M12 non-shielded proximity sensor with NPN normally open output and a 4.0 mm +/-10% sensing distance. The supplied image shows a 45 mm length reference, 12 mm body diameter, two hex nuts, and a red LED indicator. The non-shielded M12 series also lists NPN, PNP, DC two-wire, and AC two-wire output choices. Confirm cable, wiring, and target compatibility with XSZ before order.

  • Factory Direct Supply
    Stable Quality
  • Custom Options
    Support OEM/ODM
  • Technical Support
    Quick Response

Description

M12 non-shielded proximity sensor

4 mm metal sensing with NPN normally open output

The XSZ PR12-4DN is the DC NPN normally open model in the M12 non-shielded range. It is specified for a 4.0 mm sensing distance with a 15 × 15 × 1 mm iron reference target. Its threaded M12 format fits compact detection points where the machine needs a defined metal-target signal and room for non-shielded mounting.

M12 non-shielded
4.0 mm ±10%
DC NPN NO

Detection range and target conditions

The supplied specification lists a 4.0 mm ±10% sensing distance and a 0–3.2 mm setting distance. The reference target is iron measuring 15 × 15 × 1 mm. Use the setting distance when planning the actual operating gap, then check the result with the production target and its movement path.

The source identifies magnetic metal as the detectable target and warns that non-magnetic metal reduces sensing distance. A different material, target size or orientation should therefore be tested rather than assumed to work at the full reference distance.

PR12-4DN technical specifications

Sensing and mechanical

Model / mountingPR12-4DN / M12 non-shielded
Sensing distance4.0 mm ±10%, with the standard iron target
Setting distance0–3.2 mm
Standard targetIron, 15 × 15 × 1 mm
Detectable materialMagnetic metal; shorter distance with non-magnetic metal
HysteresisLess than 10% of sensing distance

Electrical and protection

OutputDC NPN, normally open (NO)
Listed DC supply12–24 VDC; confirm the permissible range before connection
Current consumptionLess than 13 mA, listed for N/P-type models
Circuit protectionReverse-connection protection, surge absorption and load short-circuit protection, listed for N/P/D types
Insulation resistanceAt least 50 MΩ at 500 VDC, between live parts and housing
Protection classIP67, listed value

Environment and materials

Operating / storage temperature−30 to +65 °C; no freezing or condensation
Relative humidity35–95% RH
HousingNickel-plated brass
Sensing faceABS

Confirm the current datasheet’s allowable supply range, rated output load, cable or connector and wire assignments for the exact supplied unit before wiring.

Related M12 output configurations

The following entries in the supplied range are separate model codes. PR12-4DN itself remains the DC NPN normally open version; its logic and wiring type are not field-selectable.

ConfigurationListed model
DC NPN NOPR12-4DN
DC NPN NCPR12-4DN2
DC PNP NO / NCPR12-4DP / PR12-4DP2
DC two-wire NO / NCPR12-4DO / PR12-4DC
AC two-wire NO / NCPR12-4AO / PR12-4AC

Selection and installation checks

  • Match the DC NPN normally open signal to the controller input; use a different model code for PNP, normally closed or two-wire operation.
  • Plan within the listed 0–3.2 mm setting distance, then verify the actual production target and travel path. Non-magnetic metal may shorten the usable distance.
  • Allow the required clearance around the non-shielded sensing end according to the current mounting drawing; no clearance dimension is supplied here.
  • Confirm supply limits, output load, connection details and environmental exposure for the exact unit before installation.

Frequently asked questions

What is the sensing distance of PR12-4DN?

The supplied specification lists 4.0 mm ±10% with a 15 × 15 × 1 mm iron reference target. The listed setting distance is 0–3.2 mm.

Is PR12-4DN NPN or PNP?

PR12-4DN is DC NPN normally open. The listed PNP normally open version is a separate code, PR12-4DP.

Can it detect aluminum or stainless steel at the full 4 mm distance?

Do not assume the iron-reference distance applies to another metal. The supplied specification says non-magnetic metals reduce the sensing distance; test the real target at its working gap.

What must be confirmed before wiring?

Check the allowable DC supply range, output load rating, connection type and wire assignments in the current datasheet for the exact delivered model.

Reviews

There are no reviews yet.

Be the first to review “PR12-4DN M12 4 mm Non-shielded Proximity Sensor”

Your email address will not be published. Required fields are marked *