Description
Compact slot sensing for small opaque parts
XSZ compact slot-type photoelectric sensors bring the emitter and receiver together around a narrow U-shaped opening. The series information lists a standard 5 mm slot width, an infrared LED light source and detection of an opaque object as small as 2 × 0.8 mm under its specified conditions.
The 45 Series and 67 Series are listed in different housing and connection formats. Select the exact model around the part that will cross the slot, the required output, mounting space and the controller connection.
What the 5 mm slot rating means
In the supplied series table, 5 mm is identified as the standard slot width. It is the distance across the opening, not a promise to detect targets 5 mm outside the sensor. The listed minimum sensing object is an opaque target measuring 2 × 0.8 mm.
To assess a small part, check its opacity, dimensions, orientation and path through the slot. Keep the target’s movement within the sensing gap and validate detection under the actual mounting and speed conditions.
Choose the housing and connection format
The older series information names the following configurations but does not provide individual ordering codes or dimension drawings. Confirm the exact variant before specifying the installation.
| Listed format | What to verify for selection |
|---|---|
| 45 Series | Exact model code, housing dimensions, mounting pattern and connection method |
| 67 Series — pre-wired | Cable length, exit direction, wiring and available output |
| 67 Series — plug-in | Mating connector, pinout, available output and mounting clearance |
NPN and PNP are listed as output options for the family. The information does not establish that a single sensor can switch between them.
Series technical data
The figures below are listed for the compact slot series. Match every value to the selected 45 or 67 Series ordering code and its current datasheet before final design.
Optical detection and response
| Standard slot width | 5 mm |
|---|---|
| Listed minimum opaque target | 2 × 0.8 mm |
| Light source | Infrared LED |
| Action / reset response | 1 ms maximum, as listed for the series |
Power, output and switching
| Supply voltage | 12–24 VDC ±10%; ripple less than 10% peak-to-peak |
|---|---|
| Current consumption | 17 mA maximum |
| Control output options | NPN or PNP open collector; select the matching model |
| Listed maximum load current | 100 mA |
| Operation mode | Light-ON / Dark-ON switching is listed; confirm availability and adjustment method for the selected model |
| Listed protection | Reverse-polarity protection and surge absorption |
Operating environment
| Operating temperature | −25 to +55 °C |
|---|---|
| Ambient illumination | Fluorescent lamp: 1,000 lx maximum |
Where compact slot detection can help
A slot sensor can provide a presence or passage signal when an opaque component crosses its opening. The listed small-target and 1 ms response values make this family worth evaluating where space is limited and parts move through a controlled path.
Examples include checking a small part as it passes a fixture, confirming position at an indexing point, or counting opaque pieces on a guided path. Suitability depends on the actual target, mounting geometry, throughput and selected output model; the series information does not establish a cleanroom rating or a guaranteed line speed.
Selection and installation checks
- Confirm that the opaque target fully crosses the sensing zone within the 5 mm slot.
- Choose the 45 or 67 Series housing and a pre-wired or plug-in connection that fits the machine.
- Select the correct NPN or PNP model and check the controller input, supply and load current.
- Verify whether Light-ON / Dark-ON switching is available on the exact model and how it is set.
- Check the mounting drawing, wiring or connector pinout, ambient light and operating temperature for the selected part number.
Frequently asked questions
Is 5 mm the detection distance outside the sensor?
No. In this series information, 5 mm is the standard width of the U-shaped sensing slot. Check the target’s position as it passes through that opening.
What is the smallest object listed?
The series table lists a minimum opaque target of 2 × 0.8 mm. Confirm its test orientation and whether your actual part produces a reliable signal in the chosen setup.
Can one unit switch between NPN and PNP?
The family lists both output types, but does not state that one unit changes between them. Choose the correct ordering model for the controller input.
Are pre-wired and plug-in connections available?
The 67 Series is listed with both formats. Confirm the exact part number, cable or mating connector and pinout before ordering.
Does every variant have a 1 ms response?
The series table lists a maximum 1 ms action/reset response. Verify this rating on the current datasheet for the selected 45 or 67 Series model and your operating conditions.





Reviews
There are no reviews yet.