PR08-2DN product overview
The XSZ PR08-2DN is an M8 non-shielded proximity sensor for a close-range metal detection point. Its model code identifies the DC NPN normally open version in the PR08 range; the listed sensing distance is 2 mm ±10%.
The separate setting-distance range is 0–1.6 mm. Both figures should be considered with the specified 12 × 12 × 1 mm iron reference target rather than assumed for every part or mounting position.
| Model | PR08-2DN |
|---|---|
| Housing / mounting | M8 / non-shielded |
| Sensing / setting distance | 2 mm ±10% / 0–1.6 mm |
| Output | DC NPN, normally open |
Plan the operating gap around the actual metal target
The listed 2 mm sensing distance is based on an iron target measuring 12 × 12 × 1 mm. For a small or differently shaped metal part, confirm the usable gap with the real target and approach direction at the intended machine position.
PR08-2DN is non-shielded, so the surrounding metal and mounting clearance matter. Check the current installation drawing before designing a bracket or recess around its sensing face.
PR08-2DN technical specifications
These values describe the listed M8 non-shielded DC NPN normally open version. Confirm wiring and mounting against the supplied unit’s current documentation.
Detection and mounting
| Thread size / installation | M8 / non-shielded |
|---|---|
| Sensing distance | 2 mm ±10% |
| Setting distance | 0–1.6 mm |
| Standard target | Iron, 12 × 12 × 1 mm |
| Detectable target | Metal (iron reference) |
| Hysteresis | Less than 10% of sensing distance |
Electrical data
| Output configuration | DC NPN, normally open (NO) |
|---|---|
| Listed DC supply | 10–30 VDC |
| Consumption current | Less than 13 mA (N/P output group) |
| Insulation resistance | At least 50 MΩ at 500 VDC, between live parts and housing |
Environment and construction
| Operating and storage temperature | −30 to +65 °C; no freezing or condensation |
|---|---|
| Humidity | 35–95% RH |
| Protection class | IP67 |
| Housing material | Nickel-plated brass |
| Sensing-face material | ABS |
Related PR08 non-shielded model codes
PR08-2DN is the DC NPN normally open product on this page. The codes below identify separate electrical or switching-logic versions, not settings that can be changed on this unit.
| Electrical type | Logic | Model code |
|---|---|---|
| DC NPN | NO | PR08-2DN — this product |
| DC NPN | NC | PR08-2DN2 |
| DC PNP | NO | PR08-2DP |
| DC PNP | NC | PR08-2DP2 |
| DC two-wire | NO | PR08-2DO |
| DC two-wire | NC | PR08-2DC |
Applications and installation checks
The M8 body can be evaluated for metal-part presence or position checks at a compact machine fixture. Test the actual part at the intended operating gap, and check that nearby metal does not interfere with the required non-shielded mounting arrangement.
Confirm before ordering
- Actual target material, size and travel path at the planned 0–1.6 mm setting distance.
- Non-shielded mounting clearance and the current mechanical drawing.
- 10–30 VDC supply and NPN NO compatibility with the controller input.
- Cable or connector type, wiring diagram and permissible output load for the unit supplied.
Frequently asked questions
Is PR08-2DN a non-shielded model?
Yes. The supplied model table identifies PR08-2DN as M8 non-shielded. Confirm the metal-free clearance around the sensing face using the current mounting drawing.
What is the difference between sensing and setting distance?
The listed sensing distance is 2 mm ±10%. The separate 0–1.6 mm setting distance is the range to use when planning a reliable target gap.
Will every metal target be detected at 2 mm?
Not necessarily. The listed reference target is iron measuring 12 × 12 × 1 mm. Check the real metal, shape and size at the planned gap.
Can I use a PNP or two-wire output with this part number?
No. PR08-2DN is the NPN normally open code. PNP and DC two-wire choices have separate model codes and require their own electrical checks.