Description
EUSL-U30 dual-channel slot detection
The EUSL-U30 series is a slot-type photoelectric level switch described for elevator leveling and related position-detection tasks. Two independent optical axes provide separate A/B detection channels, allowing the controller to monitor two positions through one sensor assembly.
The supplied series data lists a 30 mm detection distance and an opaque target larger than Ø12 mm. EUSL-U30R3C4 provides NPN output; EUSL-U30X3C4 provides PNP output. These are separate models, not output modes selectable on one device.
| Sensing format | Slot type; two independent optical axes |
|---|---|
| Detection distance listed | 30 mm |
| Target reference | Opaque object larger than Ø12 mm |
| Output selections | NPN or PNP, by model code |
Two optical axes for elevator leveling
The two sensing axes have independent outputs. In an elevator leveling arrangement, this lets the control system receive separate signals as the target passes the A and B detection positions. The source lists red and yellow channel indicators, plus a green circuit indicator, to support on-site status checks.
The actual target must be opaque and positioned to interrupt the required optical path. Confirm the target diameter, approach direction, channel spacing and installation geometry with the current drawing before treating the stated 30 mm figure as a mounting dimension.
Technical specifications
Detection and response
| Detection type | Slot-type photoelectric |
|---|---|
| Optical axes | Two, with independent A/B channel outputs |
| Detection distance | 30 mm, as listed in the supplied series data |
| Detectable object | Opaque object larger than Ø12 mm |
| Operate / reset response | 1 ms maximum |
Power, output and indicators
| Supply voltage | 10–30 VDC |
|---|---|
| Output type | Open collector; NPN or PNP according to model |
| Load current | 100 mA maximum |
| Channel indicators | Red and yellow for A/B channels |
| Circuit indicator | Green |
| Protection listed | Reverse-supply-polarity and instantaneous-overvoltage protection |
Environment and construction
| Ambient light | Sunlight: 10,000 lx maximum |
|---|---|
| Housing / lens | ABS / PC |
| Connection | Pre-wired 2 m cable |
Choose the NPN or PNP model
Select the code that matches the controller input. Both codes are listed in the supplied EUSL-U30 series data; they should be treated as separate electrical selections until the product structure and wiring are confirmed.
| Model | Output selection |
|---|---|
| EUSL-U30R3C4 | NPN open collector |
| EUSL-U30X3C4 | PNP open collector |
Application and installation checks
For elevator leveling or another slot-detection position, confirm that the moving target interrupts the intended optical axis and that the two channel signals match the controller’s required sequence. The listed opaque-target size and response time should be checked under the actual speed, spacing and ambient-light conditions.
Before specifying an EUSL-U30 model
- Choose the NPN or PNP code for the controller input; verify the A/B output wiring for that exact code.
- Check target opacity, diameter, position and travel through both optical paths.
- Verify the 30 mm dimension, channel spacing and mounting clearances using the current drawing.
- Confirm the 10–30 VDC supply, load current, 2 m cable routing and actual light/environment conditions.
Frequently asked questions
Are the two optical axes independent?
Yes. The supplied series information lists two optical axes with independent A/B channel outputs.
Can one EUSL-U30 unit switch between NPN and PNP?
No such switching is specified. EUSL-U30R3C4 is listed as NPN and EUSL-U30X3C4 as PNP; choose the model for the controller.
What target is listed for detection?
The supplied specification lists an opaque object larger than Ø12 mm. Confirm the actual target’s orientation and travel through the slot.
Is a wiring diagram available in this description?
A current model-specific diagram should be checked before connection. Confirm the channel wiring, output type and cable conductors for the selected code.