Description
SZ-M68-10DN product overview
The XSZ SZ-M68-10DN is a detection-hole sensor with a 10 mm opening and an NPN normally open (NO) output. Its product data lists a 1.0 mm minimum detection target and names iron as the standard target.
For a compact machine station, check the target’s actual size and path through the opening, the controller’s input type and the mounting space. The minimum-target value should be checked against the intended material and test conditions before selecting the sensor.
| Model | SZ-M68-10DN |
|---|---|
| Detection hole | 10 mm |
| Output | NPN NO |
| Listed minimum target | 1.0 mm |
10 mm opening and listed 1.0 mm minimum target
The 10 mm figure describes the detection-hole diameter. The target must pass through this opening with enough clearance for its motion and the surrounding tooling. The separate 1.0 mm figure is a listed minimum detection target, not the opening size.
The standard target is listed as iron. A 1.0 mm minimum does not establish identical detection for every material or shape; confirm the test target and the real part’s geometry, position and speed when evaluating this model.
Technical specifications
Review the detection, electrical and environmental data together. Use the current SZ-M68-10DN datasheet and dimensional drawing before specifying the sensor for a machine.
Detection and mechanical dimensions
| Product type | Detection-hole sensor |
|---|---|
| Detection-hole diameter | 10 mm |
| Minimum detection target | 1.0 mm; confirm target definition and test conditions |
| Standard detection target | Iron |
| Mounting holes | 2 × Ø5.6 mm |
| Mounting-hole spacing | 28 mm, center to center |
| Adjustment | Side adjustment screw |
Electrical ratings
| Output configuration | NPN, normally open (NO) |
|---|---|
| Operating voltage | 10–30 VDC |
| Consumption current | 15 mA |
| Load current | 100 mA maximum at 24 VDC |
Environmental ratings and insulation
| Operating and storage temperature | −30 to +65 °C; no freezing or condensation |
|---|---|
| Operating and storage humidity | 35–95% RH |
| Insulation resistance | At least 50 MΩ at 500 VDC, between energized parts and housing |
| Protection class | IP67 (IEC) |
Related 10 mm output models
SZ-M68-10DN is the NPN NO product described here. The other codes below are separate 10 mm models, not output settings that can be switched on this unit.
| Output type | Logic | Model |
|---|---|---|
| NPN | NO | SZ-M68-10DN — this product |
| NPN | NC | SZ-M68-10DN2 |
| PNP | NO | SZ-M68-10DP |
| PNP | NC | SZ-M68-10DP2 |
Applications and installation checks
Typical applications
- Pass-through detection of small iron parts in a compact station.
- Monitoring part passage in assembly or material-handling equipment when the target and timing match the sensor.
Installation considerations
The listed mounting pattern has two Ø5.6 mm holes with 28 mm center spacing, plus a side adjustment screw. Use the current dimensional drawing to confirm the overall housing fit. Leave clearance for the part path, cable connection and access to the adjustment screw.
What to confirm before ordering
- Real target material, shape and size relative to the 10 mm opening and listed 1.0 mm minimum.
- Required detection timing, NPN NO controller input and 10–30 VDC supply.
- Mounting clearance, side-adjustment access, cable and wiring requirements.
- Ambient temperature, humidity and any exposure relevant to the IP67 rating.
Frequently asked questions
What does the 10 mm figure describe?
It is the detection-hole diameter. The separate 1.0 mm value is the listed minimum detection target and should be checked against the actual target and test conditions.
Will it detect any 1.0 mm part?
That is not established by the size value alone. The product data names iron as the standard target; confirm the part material, shape, orientation and test conditions with XSZ.
Is SZ-M68-10DN the NPN normally open version?
Yes. SZ-M68-10DN is the NPN NO model in the four-code 10 mm group. Obtain the current wiring diagram before connecting it to the controller.
What installation details should be checked?
Confirm the housing drawing, two-hole mounting pattern, adjustment access, cable connection, target path and operating environment.







Reviews