Description
CR30-15DN product overview
The XSZ CR30-15DN is the DC NPN normally open (NO) version in the non-shielded CR30 proximity-sensor range. Its listed sensing distance is 15 mm ±10%, using a 50 × 50 × 1 mm iron plate as the standard target. The 15 mm figure describes sensing distance, not the outside size of the housing.
Use the exact DN code when an NPN NO signal is required. Confirm the real target, controller input and installation space before choosing a switching position.
Non-shielded sensing and target selection
The 15 mm ±10% reference is tied to the listed iron standard target. A different metal, target size or approach direction may change the detection result. Test a representative workpiece and allow for mounting tolerance when placing the sensor.
The source provides no verified overall housing drawing or minimum clearance around adjacent metal for this non-shielded version. Obtain the current dimensional and installation drawings before finalizing a bracket.
Technical specifications
The values below are listed for the CR30-15DN model or its DC family. Confirm the current exact-code datasheet before committing to a wiring, load or mechanical design.
Detection and output
| Shielding type | Non-shielded |
|---|---|
| Sensing distance | 15 mm ±10% with the listed standard target |
| Standard target | Iron, 50 × 50 × 1 mm |
| Hysteresis | No more than 20% of sensing distance |
| Output | DC NPN, normally open (NO) |
DC electrical ratings
| Rated supply voltage | 10–30 VDC |
|---|---|
| Current consumption | 15 mA maximum, DC family |
| Control output | 200 mA, DC family |
| Response frequency | 50 Hz, DC family |
| Residual voltage | 1.5 V maximum, DC family |
Construction and operating environment
| Operating indicator | Red LED |
|---|---|
| Cable length | 2 m |
| Operating temperature | −10 to +70 °C; no freezing or condensation |
| Storage temperature | −30 to +80 °C; no freezing or condensation |
| Ambient humidity | 35–95% RH |
| Insulation resistance | At least 50 MΩ at 500 VDC |
| Withstand voltage | 1,500 VAC at 50/60 Hz for 1 minute |
Environmental test values
| Temperature influence | From −10 to +70 °C, sensing distance within ±20% of its value at +20 °C |
|---|---|
| Vibration | 1 mm amplitude, 10–55 Hz, X/Y/Z directions, 2 hours each |
| Shock | 500 m/s² (listed as 50 G), X/Y/Z directions, 3 times each |
Related CR30 non-shielded models
CR30-15DN is the DC NPN NO product on this page. These other codes are separate NO/NC and output-family selections, not modes that can be changed on the DN unit. Check each exact model’s supply and wiring before ordering.
| Electrical/output type | Logic | Model code |
|---|---|---|
| DC NPN | NO | CR30-15DN — this product |
| DC NPN | NC | CR30-15DN2 |
| DC PNP | NO | CR30-15DP |
| DC PNP | NC | CR30-15DP2 |
| AC two-wire | NO | CR30-15AO |
| AC two-wire | NC | CR30-15AC |
Applications and installation checks
The DN model may be evaluated for metal-target presence at a fixed machine position when a 10–30 VDC supply and NPN NO controller input are available. Compare the actual target with the iron reference and check the required response timing before selecting the sensor.
Confirm before ordering
- Target metal, target dimensions and the actual sensing position.
- 10–30 VDC supply, NPN NO input compatibility, allowable load and response timing.
- Current CR30-15DN housing drawing, nearby metal clearance and cable route.
- Exact wiring diagram and whether the listed environmental test values apply to the delivered version.
Frequently asked questions
What does the 15 mm figure describe?
It is the listed sensing distance for the non-shielded CR30 configuration, measured against a standard iron target. It is not a confirmed housing dimension.
Is CR30-15DN the NPN normally open version?
Yes. The model matrix identifies CR30-15DN as DC NPN NO. PNP, NC and AC two-wire versions have separate part numbers.
Does the 15 mm reference apply to any metal part?
The standard target is a 50 × 50 × 1 mm iron plate. Test the actual material, size and approach path before relying on the listed distance.
What installation details should be confirmed?
Confirm the current housing and mounting drawing, clearance near metal, exact cable/wiring arrangement and compatible controller input.




Reviews