SZ-M12-2DN M12 2 mm Flush Mount Proximity Sensor

The XSZ SZ-M12-2DN is an M12 flush-mount proximity sensor with a rated 2 mm sensing distance and DC NPN normally open output. The supplied model table lists a 0–1.6 mm setting distance, an iron 12 × 12 × 1 mm standard target and an 800 Hz response frequency. Confirm the supply voltage, connection and wiring for the exact unit before installation.

  • Factory Direct Supply
    Stable Quality
  • Custom Options
    Support OEM/ODM
  • Technical Support
    Quick Response

Description

M12 flush-mount metal detection

SZ-M12-2DN for close-range position checks

The XSZ SZ-M12-2DN is an M12 flush-mount proximity sensor with a rated 2 mm sensing distance and DC NPN normally open output. In the supplied model table, the 2 mm version has a 0–1.6 mm setting distance and uses an iron 12 × 12 × 1 mm standard detection target.

This is the 2 mm NPN NO model, not a switchable 2/4/6 mm product. Check the actual target, controller input and mounting space before selecting it for a machine.

Rated distance versus installation distance

The 2 mm sensing distance is the table’s rated value for the specified iron target. The same table gives a 0–1.6 mm setting distance for the 2 mm version, leaving space between the nominal rating and the intended installation position.

The source identifies magnetic metal as the detectable target and notes that the distance decreases for non-magnetic metal. Test the real part’s material, size, approach direction and mounting arrangement rather than assuming every metal part will be detected at 2 mm.

SZ-M12-2DN technical specifications

The values below come from the supplied 2 mm model column and the source table’s N/P-type or shared rows. Confirm the exact orderable unit against its current datasheet before electrical or mechanical design.

Model / mountingSZ-M12-2DN / M12 flush mount
Output configurationDC NPN, normally open (NO)
Rated sensing distance2 mm
Setting distance0–1.6 mm
Standard detection targetIron 12 × 12 × 1 mm
Response frequency / time800 Hz / 0.1 ms, as listed for the 2 mm column
Repeat accuracy / hysteresis1% / less than 10% of sensing range
Consumption currentLess than 13 mA, N/P type source-table value
Listed control-output currentLess than 300 mA, N/P type source-table value; verify load rating
Circuit protectionReverse-connection protection, surge absorption and load short-circuit protection, as listed for N/P/D types
Environment−30 to +65 °C; 35–95% RH; no freezing or condensation
Insulation resistanceAt least 50 MΩ at DC 500 V, between live parts and housing
Withstand voltageAC 1000 V, 50/60 Hz, 1 minute, between live parts and housing
Housing / sensing faceNickel-plated brass / ABS

Other M12 flush-mount models in the supplied matrix

The models below are separate choices, not output or distance settings that can be changed on SZ-M12-2DN. Check each model’s own ordering and electrical data before substituting it.

SZ-M12-2DN22 mm, DC NPN NC
SZ-M12-2DP / SZ-M12-2DP22 mm, DC PNP NO / NC
SZ-M12P-4DN4 mm, DC NPN NO
SZ-M12P-6DN6 mm, DC NPN NO

Application and installation checks

SZ-M12-2DN can be evaluated for ordinary, non-safety metal-part presence or close-position feedback in machine fixtures. A flush-mount form is useful when the sensing face needs to fit into a compact mounting arrangement, but the exact mechanical clearances depend on the approved drawing.

  • Use the 2 mm model’s 0–1.6 mm setting distance as the source-table starting point, then test the actual part and mounting position.
  • Verify that the part is a suitable metal target; non-magnetic metal may be detected at a shorter distance than the standard iron target.
  • Match the NPN normally open signal to the controller’s required input and confirm the exact wiring, supply voltage and load rating.
  • Check the connection type, body dimensions and environmental protection against the actual machine layout before ordering.

Frequently asked questions

What is the difference between 2 mm sensing and 0–1.6 mm setting distance?

The supplied table lists 2 mm as the rated sensing distance for its iron reference target and 0–1.6 mm as the setting distance for installing the 2 mm model.

Does SZ-M12-2DN provide both NO and NC outputs?

No. SZ-M12-2DN is listed as DC NPN normally open. The supplied matrix lists SZ-M12-2DN2 as a separate NPN normally closed model.

Will non-magnetic metal be detected at the full 2 mm?

Do not assume so. The source notes that non-magnetic metal reduces the detection distance; test the actual part and allow an appropriate installation margin.

What must be checked before wiring?

Confirm the exact unit’s supply voltage, connection and wire assignment, controller input, output load and protection class against current product documentation.

Reviews

There are no reviews yet.

Be the first to review “SZ-M12-2DN M12 2 mm Flush Mount Proximity Sensor”