SZC-M12-2DN M12 2 mm Shielded Proximity Sensor

The XSZ SZC-M12-2DN is the shielded M12, DC NPN normally open (NO) selection in the supplied model matrix. It is listed with a 2 mm ±10% sensing distance, a 0–1.7 mm setting-distance range and a 500 Hz response frequency. The source gives 10–30 VDC operation, a 60 mm body length and an IP65 protection class. Verify the actual target material, current limits and wiring for this exact code before installation.

  • Factory Direct Supply
    Stable Quality
  • Custom Options
    Support OEM/ODM
  • Technical Support
    Quick Response

Description

SZC-M12-2DN at a glance

The XSZ SZC-M12-2DN is the shielded M12, DC NPN normally open (NO) proximity-sensor selection in the supplied model matrix. Its listed sensing distance is 2 mm ±10%, with a 0–1.7 mm setting-distance range and a 500 Hz response frequency.

This exact code is the 2 mm shielded version. The 5 mm non-shielded options and PNP/NC outputs have separate model codes; they are not settings that can be switched on SZC-M12-2DN. Verify the actual target material and installation gap before specifying it.

Exact modelSZC-M12-2DN
Body / installationM12, shielded
Sensing / setting2 mm ±10% / 0–1.7 mm
OutputDC NPN NO

Planning the 2 mm shielded sensing point

The listed 2 mm sensing distance and 0–1.7 mm setting range refer to different limits. Place the actual target within a tested operating gap, allowing for movement, mounting tolerance and the sensor’s switching hysteresis.

An M12 shielded format can suit a compact machine station where the selected output must be NPN normally open. Check target compatibility and the complete mounting drawing, including the sensing-face position and cable exit, before installation.

Technical specifications

Sensing and mechanical data

Body designationM12; 12 mm body diameter
Body length listed60 mm
Installation typeShielded
Sensing distance2 mm ±10%
Setting distance0–1.7 mm
Response frequency500 Hz
Switching hysteresisLess than 15% of rated sensing distance (Sr)
Housing materialNickel-plated copper
Sensing faceABS

Electrical data for SZC-M12-2DN

Output configurationDC NPN, normally open (NO)
Operating voltage10–30 VDC
Supply rippleLess than 10%, as listed
Leakage currentLess than 0.01 mA
Voltage dropLess than 1.5 V
IndicationLED
Circuit protectionShort-circuit protection listed

Operating environment

Protection classIP65
Operating temperature0 to +60 °C
Temperature driftLess than 10% of rated sensing distance (Sr)

The supplied reference does not resolve the no-load and maximum-load current values or show the final cable/connector wiring. Confirm both before connecting a controller or load.

Related M12 model selections

SZC-M12-2DN is the shielded NPN NO product described here. The codes below identify separate shielding and output selections; they do not change this unit’s detection distance or output logic.

Mounting / distanceOutputModel code
Shielded, 2 mmNPN NOSZC-M12-2DN — this product
Shielded, 2 mmNPN NCSZC-M12-2DN2
Shielded, 2 mmPNP NOSZC-M12-2DP
Shielded, 2 mmPNP NCSZC-M12-2DP2
Non-shielded, 5 mmNPN NOSZC-M12-5DN
Non-shielded, 5 mmNPN NCSZC-M12-5DN2
Non-shielded, 5 mmPNP NOSZC-M12-5DP
Non-shielded, 5 mmPNP NCSZC-M12-5DP2

Installation and selection checks

This M12 NPN NO sensor can be evaluated for a short-gap presence or position check when the actual target is compatible. Confirm the target material and its behavior at the planned 0–1.7 mm setting distance rather than assuming the nominal 2 mm sensing limit applies to every material.

Before specifying SZC-M12-2DN

  • Test the actual target’s material, size and travel against the planned sensing gap.
  • Confirm the M12 mounting drawing and the complete cable/connector configuration.
  • Match the 10–30 VDC supply and NPN NO output to the controller using a verified wiring diagram.
  • Obtain the exact no-load and maximum-load current ratings before selecting the connected load.

Frequently asked questions

Is 2 mm the setting distance?

No. The source lists a 2 mm ±10% sensing distance for this shielded model and a separate 0–1.7 mm setting-distance range.

Is SZC-M12-2DN an NPN normally open version?

Yes. The supplied M12 matrix maps this code to the shielded DC NPN NO selection.

Can it be set to the 5 mm non-shielded range?

No. The 5 mm non-shielded versions have separate model codes; they are not settings on this 2 mm shielded sensor.

What needs confirmation before connection?

Verify the target material, exact current ratings, cable/connector wiring and the controller input for the NPN NO output.

Reviews

There are no reviews yet.

Be the first to review “SZC-M12-2DN M12 2 mm Shielded Proximity Sensor”

Your email address will not be published. Required fields are marked *