Description
E3FA-TN21 product overview
The XSZ E3FA-TN21 is a through-beam photoelectric sensor for detecting an object as it passes between a separate emitter and receiver. The supplied product information lists a 20 m sensing distance, 10–30 VDC supply and NPN normally open (NO) output.
This arrangement is suited to detection points where the two units can be mounted across a machine or conveyor gap. The emitter and receiver must face each other, and the object must interrupt enough of the light path to produce the required signal.
| Model | E3FA-TN21 |
|---|---|
| Sensing method | Through-beam; separate emitter and receiver |
| Source-listed distance | 20 m |
| Supply and output | 10–30 VDC; NPN NO |
How the through-beam detection works
The emitter sends light toward the receiver on the opposite side of the detection area. An object is detected when it interrupts that path. Unlike a diffuse reflective sensor, this method does not depend on receiving light reflected back from the object’s surface; the actual object must still be large and opaque enough to block the beam as required by the application.
A 20 m source-listed range makes this model a candidate for wider mounting gaps, but real-world performance depends on alignment, ambient light, contamination and the target. Check the intended installation distance and allow a practical operating margin.
Technical specifications
The values below come from the supplied E3FA-TN21 product information. Use the current exact-model datasheet and wiring diagram for final electrical and mechanical design.
| Sensor type | Through-beam photoelectric sensor |
|---|---|
| Model | E3FA-TN21 |
| Detection arrangement | Separate emitter and receiver; no reflector |
| Source-listed sensing distance | 20 m |
| Supply voltage | 10–30 VDC |
| Output configuration | NPN normally open (NO) |
Applications and installation checks
E3FA-TN21 may be evaluated for object passage or presence at conveyor transfer points, packaging lines and material-handling equipment where both sides of the beam path are accessible. Suitability for counting or position confirmation depends on the target dimensions and movement speed; the supplied information does not state a response time.
Check before installation
- Provide a mounting point for both emitter and receiver and align their optical axes.
- Confirm the target blocks the beam at the planned gap, including at its normal speed.
- Match the NPN NO output and actual conductor assignments to the controller input.
- Obtain the exact-model drawing and environmental rating for bracket and location selection.
Frequently asked questions
Does E3FA-TN21 need a reflector?
No. Through-beam detection uses a separate emitter and receiver facing each other across the detection area.
Is 20 m the guaranteed distance for every object?
No. The supplied information lists 20 m as the sensing distance, but actual detection must be checked with the intended object, mounting alignment and environment.
What output does the receiver provide?
The supplied model information specifies NPN normally open (NO). Confirm the current wiring diagram, output load and controller input before connection.
Can this sensor be used as a safety protective device?
This listing does not establish a safety rating or protective-device certification. Use an appropriately rated safety device where machine guarding is required.