Enter maximum RPM
Use the shaft speed at the operating condition you need to detect, including the fastest expected case.
XSZ engineering calculator
Convert shaft speed into revolutions per second and the pulse frequency your sensor or counter must handle. Enter the number of detectable events per revolution to avoid confusing rotational Hz with output pulse Hz.
Two different frequenciesAt 1 event per revolution, pulse Hz equals rotational Hz. With multiple teeth, magnets or marks, pulse Hz rises in proportion to the events counted each turn.
Calculator inputs
Use the highest operating RPM when you are checking whether a sensor or controller can follow the pulses.
rotational Hz = RPM / 60 · pulse Hz = RPM × events/rev / 60Three inputs answer three different engineering questions. The first two perform the conversion; the published frequency limit is only a preliminary comparison.
Use the shaft speed at the operating condition you need to detect, including the fastest expected case.
Specify how many teeth, marks, magnets or output pulses the controller counts in one full revolution.
Check the calculated pulse rate against the exact sensor and input specifications, then test the real pulse width.
RPM describes mechanical rotation. Hz can describe either complete revolutions per second or electrical pulses per second. The second value depends on how many events occur in each turn.
A shaft turning at 1,500 RPM completes 25 revolutions per second. That is 25 Hz of mechanical rotation, regardless of how many targets are on the shaft.
If the same shaft presents 12 equally counted targets per revolution, the input receives an average of 300 pulses per second. The output frequency is 300 Hz, not 25 Hz.
These values assume one counted pulse for each detectable event and a constant speed.
| Speed | Events / rev | Rotational Hz | Pulse Hz | Average interval |
|---|---|---|---|---|
| 60 RPM | 1 | 1 Hz | 1 Hz | 1,000 ms |
| 1,500 RPM | 1 | 25 Hz | 25 Hz | 40 ms |
| 1,500 RPM | 12 | 25 Hz | 300 Hz | 3.33 ms |
| 3,000 RPM | 20 | 50 Hz | 1,000 Hz | 1 ms |
Interval = 1 ÷ pulse frequency. It is an average between equally spaced events, not the ON duration of a pulse.
The number is most useful as an input to a real sensor or counter selection, not as a substitute for the product datasheet.
Estimate the pulse rate from maximum shaft RPM and the number of teeth that actually produce counted transitions.
Convert rotating targets into an expected event rate before choosing a proximity or photoelectric sensor.
Compare the pulse rate with the specified input frequency, then verify pulse width, filtering and counting mode.
It is 25 revolutions per second. Electrical pulse frequency is 25 Hz only when the input counts one pulse per revolution. Multiply by the actual counted events per turn for the pulse frequency.
Enter the number of pulses counted by the specific controller input for one full shaft turn. For a single tooth or magnet counted once, enter 1. If multiple marks or teeth each create a counted pulse, enter that total.
No. The interval is the average time between successive events at a constant speed. ON time depends on target width, sensing geometry, duty cycle and device response.
An encoder’s stated pulses per revolution and the controller’s counted transitions per revolution may differ. Confirm the channel and decoding mode in the encoder and counter manuals, then enter the count actually used by your input. Do not multiply by two or four unless that is how your controller counts.
Not automatically. A frequency limit is one specification. Verify usable pulse width, ON/OFF response, target spacing, output load, controller input timing, environmental conditions and margin for speed variation.
Rotational and pulse frequency are both 0 Hz. There are no successive moving-target pulses, so an interval between pulses is undefined.
Share maximum RPM, counted events per revolution, target dimensions, sensor model and controller input. A photo or drawing of the sensing point helps.
Technical basis: OMRON rotary encoder selection guide explains response frequency as RPM ÷ 60 × resolution; NI encoder measurements guide distinguishes pulse resolution from ×1, ×2 and ×4 counting. Use the exact sensor and controller manuals for design approval.