Clear the whole feed path
Use the outside diameter of a feed tube if it goes through the ring. Add your own installation and tolerance allowance. The tool compares this requirement with listed XSZ aperture sizes.
XSZ engineering tool
Find a listed aperture that can clear your part or feed tube, then identify the sensing and controller checks needed before choosing an inductive ring sensor.
Start with your feed path
Enter the largest outside diameter that must clear the opening. This may be your tube outside diameter, not the metal part diameter. All dimensions are in millimetres.
An inductive ring sensor detects metal passing within its opening. Selecting one involves a mechanical path and an electrical detection problem, which should be checked separately.
Use the outside diameter of a feed tube if it goes through the ring. Add your own installation and tolerance allowance. The tool compares this requirement with listed XSZ aperture sizes.
Part material, smallest section, orientation and position can change detection. A small part near the centre of a large opening deserves particular bench testing; bore size alone cannot predict sensitivity.
Counting requires a usable pulse at the actual part speed and spacing. Confirm the chosen model’s response, output type and the controller input settings. Stationary presence may call for a different operating mode.
The result is a shortlist for engineering review, not a certified SKU recommendation.
Record the tube or part’s largest outside diameter at the sensing point and decide the extra diametral clearance your mechanics need.
Compare the required clear diameter with XSZ’s listed openings. Prefer the smallest opening that truly fits, then consider the next larger listed size if installation needs it.
Pass the smallest real parts through at production speed and worst-case position. Check metal type, pulse width, NPN/PNP compatibility and installation effects against the exact datasheet.
The feed geometry changes what you should enter—and what you must verify after the initial screen.
Enter the tube’s outside diameter, not the screw head width. Then test the shortest or smallest screw at its actual off-centre position and feed rate.
Allow for the spring’s largest passing orientation. If counting fast, low-mass parts, review whether the selected model supports the necessary dynamic response.
A static presence task is different from counting a transient part. Confirm the exact model’s operating mode and whether surrounding metal can affect the installation.
No. A 30 mm outside diameter leaves no diametral clearance in a 30 mm nominal opening. Include the actual part or tube envelope, tolerances and your required allowance, then choose a listed opening that physically clears it.
No. The initial size check is mechanical only. The smallest target cross-section, material, orientation and path can affect sensing. Test representative parts using the exact candidate model and its datasheet.
Not as a direct inductive metal target. If the only target is non-metal, review another sensing principle or a suitable detectable metal feature with engineering support.
Possibly, but the operating mode and control logic matter. Static presence and dynamic passage sensing are not interchangeable on every model. Confirm the model behavior and test both conditions.
No. Even when a public product title names NPN NO, confirm the actual datasheet, supply voltage, wiring, load and PLC input common. This tool does not infer undocumented output variants.
The tool will not force a smaller size. Share the required clear diameter, tube material, target details and mounting constraints with XSZ to review another size or sensing arrangement.
Send the tube outside diameter, metal part drawing or photo, smallest target, path, passage speed and controller input details. XSZ engineering can review aperture and detection together.
Technical background: Pepperl+Fuchs, inductive ring sensor design; ifm, ring sensor applications and static/dynamic operation. XSZ aperture links above reflect the new-site product list checked for this local draft; reconfirm each live product page before publication.