Description
SZC-M18-5DN product overview
The XSZ SZC-M18-5DN is the shielded M18 DC NPN normally open (NO) selection in the supplied proximity-sensor range. Its listed 5 mm ±10% sensing distance and 0–4 mm setting distance are references for planning a close-range detection point.
The housing is listed at 18 mm in diameter and 70 mm in body length. Match the actual target, available mounting space and controller input to the exact model before installation.
| Model | SZC-M18-5DN |
|---|---|
| Installation type | M18 shielded |
| Listed sensing distance | 5 mm ±10% |
| Electrical output | DC NPN, normally open |
5 mm shielded sensing and target checks
The 5 mm figure is the listed sensing distance; the separate 0–4 mm setting distance is the more practical starting point for selecting an installed gap. Neither figure proves the same response for every target material, size or shape.
Use a representative target and the intended mounting arrangement to verify detection. The supplied family table does not specify a standard test target or material-by-material range for SZC-M18-5DN.
Technical specifications
These figures come from the supplied M18 range specification. Obtain the current exact-model datasheet and drawing before finalizing a machine design.
Sensing and housing
| Installation type | M18 shielded |
|---|---|
| Body dimensions | 18 mm diameter; 70 mm body length |
| Sensing distance | 5 mm ±10% |
| Setting distance | 0–4 mm |
| Switching hysteresis | Less than 15% of Sr (source notation) |
| Indicator | LED |
DC NPN NO electrical data
| Output configuration | DC NPN, normally open (NO) |
|---|---|
| Operating voltage | 10–30 VDC |
| Supply ripple | Less than 10% (source-listed) |
| Response frequency | 0.5 kHz (DC type) |
| Voltage drop | Less than 1.5 V (source-listed) |
| Circuit protection | Short-circuit protection (source-listed) |
Materials and operating environment
| Housing material | Nickel-plated copper |
|---|---|
| Sensing face | ABS |
| Operating temperature | 0 to +60 °C |
| Temperature drift | Less than 10% of Sr (source notation) |
Related M18 model codes
SZC-M18-5DN is the shielded DC NPN NO product on this page. The other codes below are separate shielded or non-shielded output selections, not switchable modes of this unit.
| Mounting | Output | Model code |
|---|---|---|
| Shielded | DC NPN NO | SZC-M18-5DN — this product |
| Shielded | DC NPN NC | SZC-M18-5DN2 |
| Shielded | DC PNP NO | SZC-M18-5DP |
| Shielded | DC PNP NC | SZC-M18-5DP2 |
| Shielded | AC two-wire NO | SZC-M18-5AO |
| Shielded | AC two-wire NC | SZC-M18-5AC |
| Non-shielded | DC NPN NO | SZC-M18-8DN |
| Non-shielded | DC NPN NC | SZC-M18-8DN2 |
| Non-shielded | DC PNP NO | SZC-M18-8DP |
| Non-shielded | DC PNP NC | SZC-M18-8DP2 |
| Non-shielded | AC two-wire NO | SZC-M18-8AO |
| Non-shielded | AC two-wire NC | SZC-M18-8AC |
The supplied table lists the separate non-shielded group at 10 mm ±10% sensing distance and 0–8 mm setting distance. Those values do not apply to the 5 mm shielded unit.
Applications and installation checks
The shielded M18 format may be evaluated for a close-range object-presence point when the actual target, sensing gap and NPN NO controller input are confirmed. Do not assume identical response across different target materials from the distance figure alone.
Confirm before ordering
- Target material, size and shape at the planned 0–4 mm installed gap.
- 10–30 VDC supply and NPN NO input compatibility with the controller.
- Required switching speed and allowable output/load current.
- Current dimensional drawing, connection/wiring type and environmental rating.
Frequently asked questions
What is the sensing distance of SZC-M18-5DN?
The shielded model is listed at 5 mm ±10%, with a separate 0–4 mm setting distance. Verify the actual target at the intended mounting gap.
Is SZC-M18-5DN NPN normally open?
Yes. The supplied model matrix places this code in the DC NPN NO row. The other NPN, PNP and AC codes are separate versions.
Can the non-shielded range be used for this model?
No. The non-shielded M18 models have their own codes and a separate source-listed distance. The 5 mm shielded specifications describe SZC-M18-5DN.
What still needs confirmation for installation?
Confirm target compatibility, output/load current, wiring, cable and mounting details using the current datasheet for this exact model.