Description
LJC18A3-B-Z/BX at a glance
The XSZ LJC18A3-B-Z/BX is the M18 non-shielded, DC NPN normally open (NO) proximity-sensor model in the supplied 10 mm group. Its listed sensing distance is 10 mm ±10%, with a 0–8 mm setting-distance range. These are different figures: use the setting range when planning the operating gap.
The 10 mm figure is listed alongside a 50 × 50 × 1 mm iron standard-target reference. Check performance with the actual target material, size and approach before finalizing the installation.
| Exact model | LJC18A3-B-Z/BX |
|---|---|
| Body and installation | M18, non-shielded |
| Sensing / setting | 10 mm ±10% / 0–8 mm |
| Output | DC NPN NO |
Planning a 10 mm non-shielded sensing point
The non-shielded M18 format and 0–8 mm setting-distance range are the starting points for placing this sensor. The listed 50 × 50 × 1 mm iron target is a reference condition, not a promise of the same distance for every workpiece.
Compare the actual target’s material, dimensions and travel path with the reference conditions. Allow space around the non-shielded sensing end, and use the approved mechanical drawing for the final thread engagement, sensor length and cable exit.
Technical specifications
Sensing and construction
| Body designation | M18 |
|---|---|
| Installation style | Non-shielded |
| Sensing distance | 10 mm ±10% |
| Setting distance | 0–8 mm |
| Standard-target reference | 50 × 50 × 1 mm iron |
| Hysteresis | Less than 10% of sensing distance |
| Thread shown in source drawing | M18 × 1; verify against current drawing |
| Housing / sensing face | Nickel-plated brass / ABS |
| Action indication | Red indicator, as noted in the supplied drawing description |
Electrical data for the DC NPN model
| Output configuration | DC NPN, normally open (NO) |
|---|---|
| DC supply shown | 12–24 VDC (6–36 V also listed; confirm rated and allowable ranges) |
| Supply ripple | Less than 10% peak-to-peak |
| Consumption current | Less than 13 mA (source N.P-type entry) |
| Control-output entry | Less than 300 mA (source N.P-type entry; confirm load-current meaning) |
| Response frequency | 0.5 kHz for DC type |
| Circuit protection shown | Reverse-connection protection, surge absorption and load short-circuit protection (source N.P.D-type entry) |
Environment and electrical insulation
| Operating and storage temperature | −30 to +65 °C; no freezing or condensation |
|---|---|
| Operating and storage humidity | 35–95% RH |
| Insulation resistance | At least 50 MΩ at 500 VDC, between energized parts and housing |
| Temperature influence | −30 to +65 °C: within ±15% of the +23 °C sensing-distance reference; −25 to +60 °C: within ±10% of that reference |
| Voltage influence | Source lists ±15% across the rated voltage range and ±10% sensing-distance influence at rated voltage; verify test wording |
| Protection class | IP67 |
Related M18 non-shielded model codes
LJC18A3-B-Z/BX is the DC NPN NO model described above. The following codes are separate output or supply selections, not settings that can be changed on this unit. AC-type ratings do not apply to the BX code.
| Electrical type | Logic | Model code |
|---|---|---|
| DC NPN | NO | LJC18A3-B-Z/BX — this product |
| DC NPN | NC | LJC18A3-B-Z/AX |
| DC PNP | NO | LJC18A3-B-Z/BY |
| DC PNP | NC | LJC18A3-B-Z/AY |
| AC two-wire | NO | LJC18A3-B-J/EZ |
| AC two-wire | NC | LJC18A3-B-J/DZ |
Installation and selection checks
Use this code where the controller requires a DC NPN normally open signal, then validate the sensing response with the actual part at the intended gap. The listed reference target and 0–8 mm setting range should guide the first layout check, not replace an application test.
Before finalizing LJC18A3-B-Z/BX
- Confirm the actual target material, size, travel and required sensing gap.
- Match the verified DC supply and NPN NO output to the controller input and load.
- Check the current drawing for complete dimensions, mounting clearance, cable exit and wiring.
- Review the operating temperature, humidity and protection requirements for the installation.
Frequently asked questions
Is LJC18A3-B-Z/BX the NPN normally open model?
Yes. The supplied model matrix identifies this exact code as DC NPN NO. The NPN NC, PNP and AC two-wire selections have different model codes.
Is 10 mm the recommended mounting gap?
No. The listed sensing distance is 10 mm ±10%, while the setting-distance range is 0–8 mm. Test the real target before fixing the gap.
Does the listed distance apply to every material?
The supplied specification uses a 50 × 50 × 1 mm iron reference target. Response to the actual material and geometry must be checked separately.
What must be checked before wiring?
Confirm the final DC voltage range, allowable output load, cable or connector arrangement and complete wiring diagram for this exact code.








Reviews