Description
SZ-M60 series overview
The XSZ SZ-M60 detection-hole sensor range is listed with a 60 × 35 × 20 body dimension and five model-code groups: 22, 14, 10, 6 and 3. Each group includes separate NPN, PNP and DC-coded part numbers in normally open (NO) and normally closed (NC) versions.
Select an exact part number rather than treating the series name as one interchangeable sensor. Confirm what the numeric group denotes, the opening geometry, detectable target and supply/wiring requirements before finalizing a machine design.
Detection-hole format and fit checks
A detection-hole layout is considered when a part or material follows a controlled path through the sensor opening. The 60 × 35 × 20 dimension is a body-size listing; it does not establish the usable opening size for any of the five code groups.
Before choosing a group, compare the actual target material and dimensions with the required passage path and mounting clearance. The current opening drawing and target specification should be checked for the exact model code.
SZ-M60 model codes and output options
The code matrix contains five numeric groups. The numbers 22, 14, 10, 6 and 3 are retained as model identifiers here; confirm their physical meaning before using them as hole-size or sensing-distance specifications. Each cell below is a separate part number.
| Code group / output | NO model | NC model |
|---|---|---|
| 22 / NPN | SZ-M60-22DN | SZ-M60-22DN2 |
| 22 / PNP | SZ-M60-22DP | SZ-M60-22DP2 |
| 22 / DC | SZ-M60-22DO | SZ-M60-22DC |
| 14 / NPN | SZ-M60-14DN | SZ-M60-14DN2 |
| 14 / PNP | SZ-M60-14DP | SZ-M60-14DP2 |
| 14 / DC | SZ-M60-14DO | SZ-M60-14DC |
| 10 / NPN | SZ-M60-10DN | SZ-M60-10DN2 |
| 10 / PNP | SZ-M60-10DP | SZ-M60-10DP2 |
| 10 / DC | SZ-M60-10DO | SZ-M60-10DC |
| 6 / NPN | SZ-M60-6DN | SZ-M60-6DN2 |
| 6 / PNP | SZ-M60-6DP | SZ-M60-6DP2 |
| 6 / DC | SZ-M60-6DO | SZ-M60-6DC |
| 3 / NPN | SZ-M60-3DN | SZ-M60-3DN2 |
| 3 / PNP | SZ-M60-3DP | SZ-M60-3DP2 |
| 3 / DC | SZ-M60-3DO | SZ-M60-3DC |
Technical specifications
These series-level figures should be checked against the datasheet for the exact part number. In particular, confirm whether the listed AC supply range applies to a variant outside the model-code matrix above.
Electrical and supply data
| Consumption current | 15 mA |
|---|---|
| Load current | 100 mA maximum at DC 24 V |
| DC supply range | 12–24 V (6–36 V); ripple (P–P) below 10% |
| AC range requiring model confirmation | 110–220 V (36–250 V), 50/60 Hz; not assigned to a listed model code |
| Insulation resistance | At least 50 MΩ at DC 500 V, between energized parts and housing |
| Circuit protection | For N.P.D type: reverse-connection protection, surge absorption and load short-circuit protection; confirm variant applicability |
Operating environment and construction
| Operating and storage temperature | −30 to +65 °C; no freezing or condensation |
|---|---|
| Operating and storage humidity | 35–95% RH |
| Protection class | IP67 (IEC) |
| Housing material | ABS |
| Sensitivity adjustment | Side potentiometer |
Temperature and voltage influence
| Temperature influence, −30 to +65 °C | Within ±15% relative to +23 °C |
|---|---|
| Temperature influence, −25 to +60 °C | Within ±10% relative to +23 °C |
| Voltage influence | Within ±15% of the rated supply-voltage range; within ±10% sensing distance at rated supply voltage |
Applications and installation checks
Typical application settings
A controlled part-passage station, assembly machine or material-handling point may use a detection-hole sensor if the target and opening are suitable. Confirm the target material and detection result for the exact M60 model rather than assuming every version detects the same object.
What to confirm before ordering
- Exact part number and the physical meaning of its 22, 14, 10, 6 or 3 code group.
- Target material, part size, opening geometry and travel path.
- Output family, NO/NC logic, supply voltage and matching wiring diagram.
- Body-size unit, mounting space, cable arrangement and operating environment.
Frequently asked questions
Is SZ-M60 a single orderable model?
SZ-M60 names the series in this listing. Select an exact part number from the matrix above to specify the code group and output logic.
Do 22, 14, 10, 6 and 3 identify hole diameters?
Their physical meaning is not established by this model list. Request the current drawing for the exact part number before specifying an opening size.
Can every listed model use the AC supply range?
The AC range is not mapped to any of the model codes shown here. Confirm supply compatibility by exact part number before connecting a sensor.
What details help XSZ confirm the correct variant?
Share the target and passage dimensions, required output logic, controller input, available supply, mounting drawing and intended environment.